11
Model: FSH
−
6
Installation
2.05 Electrical Specifications
−
Hood ONLY
Electrical Specifications (Hood Only)
Unit
Voltage
Hz
Phase
Amps
Breaker
FSH
6
208
240
60
1
8
10
2.05.1 Electrical Connections
IMPORTANT!
• Hood is designed to operate with either 208V or 240V supply power.
• Breaker size shown applies to
hood power only
. Under
hood appliances are to be powered by separate circuits
interlocked through a relay which is controlled through the hood circuitry, such that appliances will not be
powered unless the hood is running properly.
• Food service equipment must be properly grounded in
accordance with local code, or in the absence of local
code, with the
National Electrical Code, ANSI/NFPA 70
. Improper grounding may result in electrical shock to
users. Check local electrical code to ensure that proper grounding is applied.
• Always consult a certified electrical contractor, or other qualified service technician, prior to installation to ensure
that electrical circuits are of sufficient rating for the hood and appliance load.
• Improper installation, adjustment, alteration, service or maintenance could result in serious injury or possible
death, equipment or property damage, and could void the warranty.
1. Install appropriate circuit breaker in main electrical panel, see
Section 2.05, Electrical Specifications
.
2. As required by code, route suitable sized flexible conduit from main panel to service box on hood top and
attach using appropriate connectors. See
Section 2.05.2, Routing Conduit & Wiring
.
3. Pull appropriately sized wire from the electrical panel to the hood service box. Securely connect power
supply wires to the proper terminal blocks inside the service box and reinstall cover.
4. Turn ON breaker supplying power to the Hood.
5. Press and hold in the top
[START]
portion of the
POWER
switch for a few seconds, release when the hood fan
starts running. Switch will spring back and remain in the
[ON]
position. An alarm may briefly sound until the
hood fan reaches full speed.
6. Place
POWER
switch in the
[OFF]
position and continue installation.
7.
Section 2.05.3
shows detail for connecting the appliance power supply through a hood interlocked relay.
Summary of Contents for FSH-6
Page 2: ......
Page 4: ......
Page 26: ...16 Model FSH 6 Installation ...
Page 28: ...Model FSH 6 Overview 18 5 2 1 3 8 3 01 Control Panel 4 6 7 ...
Page 30: ...20 Model FSH 6 Overview 3 02 Filter Chamber Exhaust Not shown 2 7 8 1 5 3 4 9 9 6 ...
Page 34: ...24 Model FSH 6 Overview ...
Page 60: ...50 Model FSH 6 Parts List 7 03 Control Panel 7 5 6 8 10 4 3 2 9 1 Inside Panel Not Shown ...
Page 64: ...54 Model FSH 6 Parts List Not shown 4 5 2 1 3 1 3 6 7 05 Under Hood Components ...