21
Model: FSH
−
6
Overview
3.02
Filter Chamber & Exhaust
Item
Description
Function
1
Hood Filter Door (2)
Provides access to filter chamber & hood filters (pre
filter, E.A.C.
cell & charcoal). Both doors must be closed and latched before
the hood will operate.
2
Baffle Filter (2)
The first stage of ventless air cleaning system. Stainless steel baffles
capture largest grease particulate ... filters easy to remove for
cleaning.
Baffle filters should be cleaned daily
.
3
Pre
Filter (2)
Single
use, disposable fiber filters remove moisture and some
additional grease
laden vapor from the air stream. Helps to keep the
E.A.C. cells performing effectively.
NEVER attempt to clean and re
‐
use pre
‐
filters ... replace every 7
‐
10 days with fresh NEW
.
4
E.A.C. Filter Cells (2)
(Left & Right)
E.A.C. collector cells are sustainable electrostatic devices that remove
fine particulate grease
laden vapor and smoke generated by the
cooking appliances.
To maintain peak performance, E.A.C. cells
must be cleaned DAILY as described later in this manual.
5
Charcoal Filter (2)
Single
use, disposable filters that help to control cooking aromas in
exhausted air. Filters must be replaced periodically.
NEVER attempt
to clean and re
‐
use charcoal filters ... Typically, replace with fresh
NEW filters every 30 to 45 days. Replacement cycle is dependent on
appliances in use, cooking activity and type of foods being cooked.
NO FILTER WILL COMPLETELY REMOVE COOKING ODORS.
6
Hood Stand
Hood mounts onto a full skirt, self
supporting floor stand.
Facilitates performance for capturing grease
laden cooking vapor
and allows you to utilize the full width of the hood, without side
clearance limitations.
7
Exhaust Outlet
Directs cleaned air back into the space.
A minimum clearance of
14” MUST be maintained between the top of the exhaust duct
outlet and ceiling, or other obstruction
.
DO NOT attempt to direct exhaust into a different space by
attaching any type ductwork ... back
‐
pressure will cause poor
performance.
8
Grease Drip Cup
Catches and collects grease condensate generated at the baffle
filters. Cup should be emptied and cleaned daily.
9
E.A.C. Drip Pan (2)
Catches and collects grease residue which may drip from E.A.C.
collector cells. Inspect daily ... empty and clean as needed.
* Not shown
Summary of Contents for FSH-6
Page 2: ......
Page 4: ......
Page 26: ...16 Model FSH 6 Installation ...
Page 28: ...Model FSH 6 Overview 18 5 2 1 3 8 3 01 Control Panel 4 6 7 ...
Page 30: ...20 Model FSH 6 Overview 3 02 Filter Chamber Exhaust Not shown 2 7 8 1 5 3 4 9 9 6 ...
Page 34: ...24 Model FSH 6 Overview ...
Page 60: ...50 Model FSH 6 Parts List 7 03 Control Panel 7 5 6 8 10 4 3 2 9 1 Inside Panel Not Shown ...