9
Installation
GGF-400, GGF-720
2.6.
Electrical Connections
1. Connect Fryer power cord to an appropriate receptacle ... the circuit must have properly sized circuit breaker
and wiring of sufficient gauge to power the appliance, See
Table 2.5.1
.
2. Fryer is equipped with power cord with molded plug.
IMPORTANT!
When installed, appliance must be electrically grounded in accordance with local code, or in the absence of local
code, with the
National Electrical Code, ANSI/NFPA 70
, or
Canadian Electrical Code, CSA C22.2
, as applicable.
2.7.
Gas Line Connection
Verify that a proper facility gas supply line (1/2” min.) is install and equipped with a “service” Shut-Off Valve
(not
provided)
. See
Section 2.8.1, Typical Gas Supply Line Connections
.
• Combustion gases produced by this appliance must be vented to the outside in accordance with the prevailing
National Fuel Gas Code, ANSI Z223.1 and terminate with a UL listed outside vent terminal. For Canadian
installations reference CSA-B149.1 or .2, Installation Codes for Gas Burning Appliances and Equipment.
• Quick-disconnect devices must comply with the Standard for Quick-Disconnect Devices for Use with Gas Fuel,
ANSI Z21.41 [in Canada CSA 6.9-2014].
• Gas Connectors and Lines must comply with Standard for Movable Gas Appliance, ANSI-69, and Addenda Z21.69
[in Canada CSA 6.10-2015].
• This unit MAY require installation of a secondary in-line gas pressure Regulator (customer supplied), see
Section
2.5, Utility Requirements & Table 2.5.2, Fuel Gas Specifications
.
• This unit MUST only be installed by a Qualified Gas Technician.
• Ensure both the Facility Shut-Off Valve and the Fryer Shut-Off Valve are in the [OFF] position.
Continued on Next Page
Summary of Contents for GGF Series
Page 13: ...4 Model GGF 400 GGF 720 Introduction ...
Page 26: ...Model GGF 400 GGF 720 Overview 18 3 1 Control Panel 5 6 4 3 2 1 7 ...
Page 28: ...20 Model GGF 400 GGF 720 Overview 3 2 Lower Cabinet 5 6 4 3 2 1 7 ...
Page 32: ...24 Model GGF 400 GGF 720 Overview 3 4 Basket and Elevator Assembly 3 1 2 4 ...
Page 38: ...30 Model GGF 400 GGF 720 Overview Notes ...
Page 42: ...34 Fryer Preparation Model GGF 400 GGF 720 ...
Page 80: ...72 Troubleshooting Model GGF 400 GGF 720 ...
Page 88: ...80 Parts List 8 5 Plumbing Model GGF 400 GGF 720 1 2 2 3 3 4 5 6 7 7 7 7 8 10 11 9 12 ...
Page 90: ...82 Parts List 8 6 Basket Basket Cover Model GGF 400 GGF 720 1 2 3 ...
Page 94: ...86 Parts List Notes Model GGF 400 GGF 720 ...
Page 95: ......