56
Model: GGF-400, GGF-720
Fryer Operation
Always wear thermal protection, such as Gloves or Oven Mitts, while performing the
filtering process. Fryer parts inside the cabinet will be extremely HOT!
5.3 Filtering Cooking Oil - continued
4. Open the cabinet door, disconnect the
Filter Pan Hose
④
(push
white slip-ring in, and pull hose from connector)
... remove
Filter
Pan
⑤
from unit.
5. Remove
Pan Cover
⑥
and check that filter media (typically, 1
sheet of filter paper) is in place and that residue from previous
filter cycles has been cleaned from the surface. Ensure that
Hold-down Frame
is properly locked in place.
6. Evenly distribute approximately
5 ozs
of a suitable
filter aid
product over the media surface. Use of a quality filter aid is
essential for removing soluble impurities and reconditioning the
oil.
Portion packed Filter Powder is available through Giles
dealers or distributors ... Item #72004.
7. Replace
Pan Cover
and reposition assembled
Filter Pan
under the unit; reconnect
Filter Pan
Hose
④
(push in white slip-ring while inserting brass fitting into connector)
.
Ensure that
hose fit is tight and secure
.
4
5
6
The next steps require that cooking oil be drained into the filter pan, thus exposing the
heating elements. Fryer is equipped with safety interlocks which disable heating elements
anytime the drain valve is opened. As further safeguard to reduce risk of oil fire, always place Selector Switch in
the [OFF] position prior to draining. NEVER CONSIDER THE DRAIN VALVE AS AN “ON/OFF SWITCH”
.
NOTE:
Be sure filter pan cover is in place while draining to contain
any oil splash and splatter.
If pot does not readily drain, use the provided
Kettle Drain
Brush
to break up crumbs or debris that might be blocking
the drain opening.
Be careful not to push brush so far down
as to puncture filter media in the Filter Pan. Doing so could
allow excessive debris to enter the filter pump, potentially
clogging and damaging it
.
8. Ensure
Selector Switch
is in the
[OFF]
position ...
Power Switch
must remain
[ON]
. Place the
Oil Diverter Valve
⑦
in the
[TO FRYPOT]
position. Slowly turn the
Drain Valve Handle
⑧
to the
[OPEN]
position. Allow used
oil to completely drain into
Filter Pan
⑤
.
8
7
5
Summary of Contents for GGF Series
Page 13: ...4 Model GGF 400 GGF 720 Introduction ...
Page 26: ...Model GGF 400 GGF 720 Overview 18 3 1 Control Panel 5 6 4 3 2 1 7 ...
Page 28: ...20 Model GGF 400 GGF 720 Overview 3 2 Lower Cabinet 5 6 4 3 2 1 7 ...
Page 32: ...24 Model GGF 400 GGF 720 Overview 3 4 Basket and Elevator Assembly 3 1 2 4 ...
Page 38: ...30 Model GGF 400 GGF 720 Overview Notes ...
Page 42: ...34 Fryer Preparation Model GGF 400 GGF 720 ...
Page 80: ...72 Troubleshooting Model GGF 400 GGF 720 ...
Page 88: ...80 Parts List 8 5 Plumbing Model GGF 400 GGF 720 1 2 2 3 3 4 5 6 7 7 7 7 8 10 11 9 12 ...
Page 90: ...82 Parts List 8 6 Basket Basket Cover Model GGF 400 GGF 720 1 2 3 ...
Page 94: ...86 Parts List Notes Model GGF 400 GGF 720 ...
Page 95: ......