70
Troubleshooting
Model: GGF-400, GGF-720
7.1.
Temperature Control System - continued
Problem
Probable Cause
Repair Procedure
OIL SMOKING:
A. Cooking oil is old.
Change cooking oil.
B. Cooking temp too high.
Check settings.
C. Low oil level.
Maintain oil at
[FULL]
level.
D. Cooking oil has been
contaminated.
Change cooking oil.
Problem
Probable Cause
Repair Procedure
OIL NOT RETURNING TO FRY POT:
A.
Selector Switch
not placed in
[FILTER PUMP]
position.
Place switch in proper position.
B. Air leak in system.
Check hoses and connections.
C. Faulty pump motor.
Inspect; replace if needed.
D. Pump head clogged or bound.
Remove head cover; clean out
pump as needed.
E.
Diverter Valve
not in
[FRYER]
position.
Place valve handle in proper
position.
F. Oil has congealed inside pump
head.
Run clean hot oil through system.
G. Oil is too cool to be pumped
efficiently (below 200
°
F/93
°
C).
Remove filter pan from fryer and
manually remove cool oil.
H. Filter Pan is assembled
incorrectly.
Assembly Filter Pan correctly; see
Section 6.2
.
I. Pump has been damaged by
pumping boil-out solution
through it.
Disassemble pump head; clean and
re-oil.
7.2.
Oil Filtration System
Summary of Contents for GGF Series
Page 13: ...4 Model GGF 400 GGF 720 Introduction ...
Page 26: ...Model GGF 400 GGF 720 Overview 18 3 1 Control Panel 5 6 4 3 2 1 7 ...
Page 28: ...20 Model GGF 400 GGF 720 Overview 3 2 Lower Cabinet 5 6 4 3 2 1 7 ...
Page 32: ...24 Model GGF 400 GGF 720 Overview 3 4 Basket and Elevator Assembly 3 1 2 4 ...
Page 38: ...30 Model GGF 400 GGF 720 Overview Notes ...
Page 42: ...34 Fryer Preparation Model GGF 400 GGF 720 ...
Page 80: ...72 Troubleshooting Model GGF 400 GGF 720 ...
Page 88: ...80 Parts List 8 5 Plumbing Model GGF 400 GGF 720 1 2 2 3 3 4 5 6 7 7 7 7 8 10 11 9 12 ...
Page 90: ...82 Parts List 8 6 Basket Basket Cover Model GGF 400 GGF 720 1 2 3 ...
Page 94: ...86 Parts List Notes Model GGF 400 GGF 720 ...
Page 95: ......