background image

6

OPERATION AND MAINTENANCE

Safety

In order to guarantee the safety of the users at all times, it is abso-

lutely necessary that the swing door installation be checked by a 

competent specialist, prior to the first commissioning and at least 

once a year during the operation, with regard to its safe operating 

condition! The result of the check-up must be documented in the 

control booklet.

Should any malfunctions occur which are detrimental to the safety 

of the door users, the mains supply must be disconnected. A manual 

operation of the door is still possible. The drive unit may only be 

taken back into operation after the malfunction has been repaired 

by a specialist and all risks have been eliminated!

Transparents door wings (or their surfaces) must be clearly reco-

gnizable, e.g. by means of a permanent marking or dyed materials.

Care and checking to be carried out by the operator

Before carrying out any work on the swing door drive unit, make sure 

that the mains power supply has been disconnected. The drive unit 

covering must not be removed!

Never use running water or  high-pressure machines  for cleaning 

the area of the drive unit! Do not use any  abrasive or chemical 

products for cleaning the installation!

Checking and maintenance to be carried out by the after-sales 

service

Prior to the first commissioning, and at least once a year during 

normal operation, the safe operating condition of the installation 

must be checked by an authorized specialist!

We recommend to conclude a maintenance contract with the manu-

facturer respectively with his authorized distribution partner.

The checking and maintenance work must be performed according to the checklist 

contained in the control booklet FDC-B France. The correct execution must be con-

firmed by the after-sales service technician who enters the date and his signature in 

the control booklet.

Summary of Contents for FDC-B

Page 1: ...0547 999 47b 2010 04 Fire rated swing door drive unit FDC B France Operator Manual Original ...

Page 2: ...carried out by the after sals service 6 TROUBLESHOOTING 7 PROLONGED OPERATING INTERRUPTION 8 SHUT DOWN DISPOSAL OF THE INSTALLATION 8 INDIVIDUAL SETTINGS MADE BY THE AFTER SALES SERVICE 9 APPENDIX 12 Declaration of incorporation according to machinery directive These instructions use the following signs in order to point out certain dangers and important remarks Warning Involving danger to life an...

Page 3: ...Franceswingdoordrive unit it is absolutely necessary that the assembly operating maintenance and repair conditions specified by the manufacturer be fulfilled If these instructions are neglected the manufacturer respectively his distribution partner cannot be held responsible Should any malfunctions occur which are detrimental to the safety of the users and which cannot be repaired without delay th...

Page 4: ... locked 0 MANUAL Corresponds to the operating mode without mains power The door wing can be manually pushed to the open position while or the closure is achieved by means of spring power NIGHT The door is locked during the night 2 OPEN The installation opens and remains in the open position Control Thedooropeningisperformedeitherautomaticallyormanuallyviathecontrolelements The door is automaticall...

Page 5: ...ion The following opening movement is then performed in the normal manner Obstruction in closing direction If the door leaf encounters an obstacle during the closing motion the drive unit is stopped and the door leaf opens up to the OPEN position During the following clo sing motion the door leaf moves at the programmed closing speed up to the position of the obstacle and from there provided that ...

Page 6: ...trolled fashion by means of spring power After the door has been opened by an escaping person it is closed in a controlled way by spring power As soon as the fire alarm has been invalidated the reset button installed on one side of the drive unit must be actuated upon which the drive unit continues to operate in the mode which had been activated prior to the fire alarm Fire protection testing The ...

Page 7: ...rials Care and checking to be carried out by the operator Before carrying out any work on the swing door drive unit make sure that the mains power supply has been disconnected The drive unit covering must not be removed Never use running water or high pressure machines for cleaning the area of the drive unit Do not use any abrasive or chemical products for cleaning the installation Checking and ma...

Page 8: ...o position 1 Mains switch installed by switch on customers switched off Power plug pulled out plug in customer s fuse defective replace fire detectors have been actuate the reset triggered key button Buzzer sounds functional fatal contact the after error sales service TROUBLESHOOTING ...

Page 9: ...t specialist before it is taken back into operation SHUT DOWN DISPOSAL No particular measures have to be taken by the operator with regard to the shut down dismantling and disposal of the installation The installation must be disassembled into its individual parts in order to be able to recycle them We advise you to entrust your after sales service with the dismantling and disposal of your install...

Page 10: ...9 INDIVIDUAL SETTINGS MADE BY THE AFTER SALES SERVICE ...

Page 11: ...10 INDIVIDUAL SETTINGS MADE BY THE AFTER SALES SERVICE ...

Page 12: ...k your distribution partner Manufacturer Gilgen Door Systems AG Freiburgstrasse 34 CH 3150 Schwarzenburg Phone 031 734 41 11 Telefax 031 734 43 79 Your after sales service Handed over to the operator Date Signature This document remains with the operator of the door installation ...

Page 13: ...e Machinery Directive 2006 42 EC Appendix I Articles 1 1 2 1 1 3 1 1 5 1 2 1 1 2 4 1 2 6 1 3 1 1 3 2 1 3 4 1 3 7 1 5 1 1 6 1 7 The technical documentation according to Appendix VII Part B has been established and will be transmitted to the authorized services in the form of electronic files upon justified request In addition the requirements specified in the directives for low voltage installation...