WindObserver II Pipe Mount
Page 32
Issue 04
Doc. No. 1390-PS-0009
August 2009
Hx - Heating
Setting
Configuration code
Disabled
H1
Activated
H2
Heating is autonomous and requires no set-up once activated. Each transducer is heated
independently and will be active when ambient temperature drops below approximately
+15ºC. Each transducer will de-activate when +25ºC threshold is reached.
Jx – Not Applicable
Kx – NMEA Settings
Setting
Configuration code
NMEA string “IIMWV”
K1
NMEA string “WIMWV”
K2
Lx - ASCII Message terminator
Setting
Configuration code
CR LF
L1
LF
L2
Mx to MXX – Message Format
Output format
Configuration code
ASCII UV Continuous
M1
ASCII Polar Continuous
M2
ASCII UV Polled (tri-state) *
M3
ASCII Polar Polled (tri-state) *
M4
NMEA Continuous
M5
Tunnel Continuous
M6
Binary UV Continuous
M7
Binary Polar Continuous
M8
* If units are to be networked, they MUST be given unique Unit Identifiers