WindObserver II Pipe Mount
Page 33
Issue 04
Doc. No. 1390-PS-0009
August 2009
Nx - Node Address
Item
Options
Command
Node Address
A…
-(
A to
Z)
N<A>
If used in a multi-drop system then it is recommended that ID’s A to F and K, M, N and P
are not used, as these characters can be present in the data string.
Ox – ASCII Output Format (Output String Padding)
Setting
Configuration code
Comma Separated Variable (CSV)
O1
Fixed Field
O2
Example data strings:-
POLAR
NMEA
CSV
data changing to error status code
condition.
CSV
data changing to error
status code condition.
A,235,000.77,M,00, 0A
$IIMWV,191,R,000.55,M,A*19
A,,,M,04, 24
$IIMWV,,R,,M,V*29
Fixed Field
data changing to error status
code condition.
Fixed Field
data changing to error status
code condition.
A,266,000.73,M,00, 08
$IIMWV,191,R,000.55,M,A*19
A,999,999.99,M,04, 0A
$IIMWV,999,R,999.99,M,V*07
Px - Output rate
Outputs per second
1
2
4
5
8
10
Configuration code
P1
P3
P2
P4
P5
P6
Q – Measurement Mode
See Section 9.3.
Tx – Not Applicable.
Ux – Digital Output Units
Units
metres/sec
(m/s)
knots
(knots)
miles/hour
(mph)
kilometre/hour
(kph)
feet/minute
(fpm)
Configuration code
U1
U2
U3
U4
U5