30
Grounding (Earthing)
For protection against lightning the WindMaster
MUST
be earthed via its mountings.
The unit MUST be connected to an appropriate grounding point with a minimum of 6mm² copper wire.
Mounting WindMaster (1590-PK-020/W +options and WindMaster Pro (1561-PK-020/W + options).
Cable strain relief
Fit strain relief when installing such that the weight of the cable is supported and does not put a strain on the connector.
Flange mounting
Mount the unit to a suitable surface, using the flange gasket and the M6 nuts, bolts and washers provided, ensuring that
the clearance for the connector is maintained as shown on Figure 4.
Figure 4 Flange Mounting
Connect Earth Lead to
a nearest Earth Point