WindMaster and WindMaster Pro
1561-PS-0001.
Issue 11 February 2017
________________________________________________________________________________________________________________________
9
4. SPECIFICATION
Parameter
WindMaster/WindMaster RA
WindMaster Pro
Outputs
Output rate
0.25, 0.5,1, 2, 4, 8, 10, 16, 20, (32
option) Hz
0.25,0.5.1, 2, 4, 8, 10, 16, 20, 32 Hz
Sample rate (automatically selected)
20 or 32 Hz
20 or 32 Hz
Units of measure
m/s, mph, KPH, knots, ft/min
m/s, mph, KPH, knots, ft/min
Format
UVW or Polar
UVW or Polar
Averaging
Flexible 0 - 3600 s
Flexible 0 - 3600 s
Wind Speed
Range
0 - 50 m/s
0 - 65 m/s
Resolution
0.01 or 0.001 m/s
0.01 or 0.001 m/s
Accuracy (12 m/s) (to special order) #
Accuracy (12 m/s)(Standard)*
‘w’ improvement multiplication factor
applied as table, allows comparison to
data previously collected with older
WindMaster units with firmware 2329-
601 or lower without multiplication
factor.
< 1.0 % RMS
< 1.5% RMS
w component only:
+w = 1.166, -w = 1.289
< 1.0 % RMS
< 1.5% RMS
w component only:
+w = 1.166, -w = 1.289
Direction
Range
0 – 359.9
0 – 359.9
Resolution
1
0
or 0.1
0
1
0
or 0.1
0
Accuracy (12 m/s) (Standard)*
2
2
Accuracy (12 m/s) (to special order)* #
0.5
0.5
Speed of Sound
Range
300 -370 m/s
300 -370 m/s
Resolution
0.01 m/s
0.01 m/s
Accuracy
<
0.5% @ 20
C
<
0.5% @ 20
C
Power requirement
9 -30 V dc, (55 mA @ 12 V dc)
(excluding analogue outputs)
9 -30 V dc, (55 mA @ 12 V dc)
(excluding analogue outputs)
Digital output
Protocol
(ASCII and Binary)
RS232, RS422, (RS485 WindMaster
Networking)
RS232, RS422,( RS485 WindMaster
Networking)
Baud rates
2400 - 57600
2400 - 57600
Analogue outputs (optional)
4 channels
Resolution 12 or 14 bit
Resolution 14 bit
Selectable range
User selectable full scale wind speed
User selectable full scale wind speed
Output type
0-20 mA, 4-20 mA, 0-5V,
5V,
2.5V
0-20 mA, 4-20 mA, 0-5V,
5V,
2.5V
Analogue inputs (optional)
Up to 4 single-ended
or 2 differential
Resolution 12 or 14 bit
Resolution 14 bit,
plus PRT 100ohm (option)
Input range
5 V
5 V
Sonic temperature
Range
T
s
'
Accuracy (
≥ 1 Hz) (All models,
unchanged)
T
s
Accuracy (slow response, used as
ambient thermometer, unit firmware
2329-700 or higher)
-40
C to +70
C
Eddy Covariance Quality
2
C between -20
C to +30
C
-40
C to +70
C
Eddy Covariance Quality
2
C between -20
C to +30
C