Installation
MetPak Base Station User Manual
©
Gill Instruments Ltd
Last Change
Page 6
22 April, 2013
2.2
Installation
2.2.1
Bench system test
Prior to physically mounting the MetPak Base Station in its final location, we
strongly recommend that a bench system test is carried out to confirm the system
is configured correctly, is fully functional and electrically compatible with the
selected host system and cabling (preferably utilising the final cable length). The
required data format, units, output rate, and other options should also all be set up
at this stage.
2.2.2
Bench Test Equipment Required
1723-2A-X-XXX/X MetPak Base Station set for RS232 communication (factory
default setting).
1723-10-051
MetPak Base Station RS232 to USB 1.8M configuration cable with
integral 5v power (for WindSonic units only). Otherwise use RS232
I/F converter and separate 12v to 30 dc power supply.
ES-U-1001-A EasySynch RS232 to USB adaptor or equivalent (if not using Gill
part 1723-10-051) or connect directly to an RS232 COM port.
Power Supply 12Vdc to 30Vdc at 100mA if required.
Belden 9503 3 pair communications and power cable (if not using Gill Part 1723-
10-051), length as required.
Belden cable with up to 6 pairs for Analogue, Digital and PRT inputs.
Gill MetSet Software supplied on the MetPak Base Station CD or download from.
http://www.gill.co.uk/main/software.html
Wind Sensor- should be configured as per the following list:-
1405-PK-072 WindSonic Option 2 White
M4,U1,O1,L1,P1,B4,H2,NQ,F1,E2,T1,S4,C2,G0,K0,
1405-PK-200 WindSonic M Heated
M4,U1,O1,L1,P1,B4,H2,NQ,F1,E2,T1,S4,C2,G0,K0,
1390-70-B-312 WindObserver 70 heated with short connector base.
Note - Firmware Version V 6.02 onwards
M4,U1,O1,L1,P1,B4,H2,NQ,F1,E2,T1,S4,C2,G0,K0,
1590-PK-020 WindMaster
M4,U1,O1,L1,P1,B4,H2,NQ,E1,T1,S1,C2,A4,I1,J1,V1,X1,G0,K0,F1 1,F2 0,F3 1
1561-PK-020 WindMaster Pro
M4,U1,O1,L1,P1,B4,H2,NQ,E1,T1,S1,C2,A4,I1,J1,V1,X1,G0,K0,F1 1,F2 0,F3 1
For Power Supply/Supplies and cables suitable for the chosen Wind sensor see
relevant wind sensor manual supplied with the sensor or download from
http://www.gill.co.uk/data/manuals/manuals.htm
.