Installation
MetPak Base Station User Manual
©
Gill Instruments Ltd
Last Change
Page 8
22 April, 2013
Whilst squeezing the red retainer in the direction of ARROWS A, pull in the
direction of ARROW B.
A
A
B
Your connector should now resemble the connector in the picture below.
Insert each contact pin until you feel a slight click. If you have inserted the contact
into the incorrect hole it can be removed at this point by simply pulling it out.
Please note there will be some resistance.
WindSonic (Option 2) RS422 10 Metre Cable Connections
Connections for the WindSonic connector are as follows:-
Green/White wire to Connector Pin 1
1
9
5
3
7
4
2
6
8
Orange/White wire to Connector Pin 2
White/Orange wire to Connector Pin 3
Brown/White wire to Connector Pin 4
White/Brown wire to Connector Pin 5
Rear View of Connector
Blue/White wire to Connector Pin 6
White/Blue wire to Connector Pin 7
White/Green cut off at sleeve