Installation
MetPak Base Station User Manual
Last Change
©
Gill Instruments Ltd
22 April, 2013
Page 19
2.2.6
Mounting MetPak Base Station
MetPak Base Station uses a mounting clamp suitable for attaching to a vertical
pipe with a diameter of 30-58mm. When mounting the MetPak Base Station,
consider the position, orientation and alignment of the unit.
Note that the mounting pipe should first be degreased and when assembling the
MetPak Base Station clamp assembly the outer clamp nuts need to be tightened
evenly to a torque figure of 3 Nm.
The moving plate part of the clamp needs to be reversed for poles below 38 mm
diameter.
Mounting Bracket Assembly Exploded View
Mounting Bracket Assembled View
Earthing Point for supplied
screw/washer/tag