Understanding Logged Data
Logged data is stored to a file with a
.log
extension. This can be viewed in any
text/HTML editor or spreadsheet application.
Figure 19 A typical 2 Axis data log (viewed in Windows Notepad)
Each entry in the default reporting order consists of the following (2 axis data illustrated):
000001 Thu Jun 17 16:08:53 2010, Q,113,000.07,1019.4,035.1,+024.7,+008.3,+04.9,00, 5F
Line Number
Date/time stamp
Node letter
Wind direction
Wind speed
Pressure
Humidity
Temperature
Dewpoint
Supply voltage
Status code