Operation
MetPak Base Station User Manual
Last Change
©
Gill Instruments Ltd
22 April, 2013
Page 35
3.3
MetPak Base Station
Configuration
MetPak Base Station can be configured using:-
Gill MetSet or a terminal program such as Windows HyperTerminal.
Gill Wind software used as a Terminal Program only.
The default configuration settings are listed in the following table.
Table 9
Default configuration settings
Setting
Function
Comms Levels
RS232
Baud Rate
19200
Data Connection
Data Bits 8, Parity None, Stop Bits 1, Flow Control None.
Node ID
Q
Output rate
1Hz
Message Mode
Continuous
ASCII Set Up
Carriage return and line feed, Echo on
North Alignment
0
Sensor WindSpeed
On
Wind Speed Units
MS (Metres/Second)
Temperature Sensor
On
Temperature Units
C (Degrees Celsius)
Dewpoint Sensor
On
Dewpoint Units
C (Degrees Celsius)
Pressure Sensor
On
Pressure Units
Hecto Pascals
Humidity Sensor
On
Humidity Units
%
Report Format
Node, Polar (Wind Direction and Wind Speed), Pressure,
Humidity, Temperature, Dewpoint, Volts, Status,
Checksum.
Status Message Output
On
Report Message Output
On
Units Message Output
On
Inputs Message Output
On
Output Sentence
Comma Separated Variable