Operation
MetPak Base Station User Manual
Last Change
©
Gill Instruments Ltd
22 April, 2013
Page 43
The Reporting Page
with a
2 Axis
Wind Sensor connected can be used to select:-
Report Format
USERDEF
, FULL
or NMEA.
Select Parameters to Report
NODE,DIR,SPEED,PRESS,RH,TEMP,DEWPOINT,VOLT,STATUS.
NODE,U-AXIS,V-AXIS,PRESS,RH,TEMP,DEWPOINT,VOLT,STATUS.
Report parameters can be selected in any order or on or off in USERDEF.
The Reporting Page
with a
3 Axis
Wind Sensor connected can be used to select:-
Report Format
USERDEF
or FULL (NMEA not Applicable)
Select 3 axis Parameters to Report e.g.
NODE,DIR,SPEED,W-AXIS,PRESS,RH,TEMP,DEWPOINT,VOLT,STATUS.
NODE,U-AXIS,V-AXIS,W-AXIS,PRESS,RH,TEMP,DEWPOINT,VOLT,STATUS.
The PowerUp Page
can be used to select:-
Status Message Output
ON
or OFF.
E.g.
METPAK BASE STATION 2436 VB.44,
STARTUP: OK.
Report Message Output
ON
or OFF.
2 Axis
NODE,DIR,SPEED,PRESS,RH,TEMP,DEWPOINT,VOLT,STATUS,CHECK.
3 Axis
NODE,DIR,SPEED,W-AXIS,PRESS,RH,TEMP,DEWPOINT,VOLT,STATUS,CHECK.
Units Message Output
ON
or OFF
E.g. 2 Axis -
DEG,MS,HPA,%,C,C,V,-,-
3 Axis
DEG,MS,MS,HPA,%,C,C,V,-,-
NOTE:-
Once all settings have been chosen then save Edited Page Settings to MetPak Base
Station by clicking on ‘Save Settings to Device’ this will change the MetPak Base Station