MetPak Base Station User Manual
©
Gill Instruments Ltd
Last Change
Page ii
22 April, 2013
Dew Point
Resolution
0.1
C (0.1
F)
Accuracy
0.15
C (23
C ambient temp @20
C dew point)
Units of Measure
C or
F
Barometric Pressure
Range
600 to 1100hPa
Accuracy
0.5hPa
Resolution
0.1hPa
Units of Measure
hPa, mbar, mmHg, InHg
Compensated for Temperature dependency –20
C to +70
C
Outputs
Digital Outputs
RS232, RS422 RS485
*
or SDI-12
Baud Rates
1200 (SDI-12), 4800-57600 (ASCII RS232, RS422)
Protocols
ASCII or SDI-12 V1.3
Data Output
0.25, 0.5, 1 Hz or Polled Mode.
MetPak Base Station Status
Status codes provided within the data message string
*
RS485 2 wire point to point only.
Power Supply
Input voltage (RS232,
RS422, RS485)
12v to 30v dc
Current
Default setting (first value is Base Station current)
15mA + 9mA at 12v with WindSonic Option 2
15mA + 9mA at 12v WindSonic M (plus heater power)
15mA + 50mA at 12v WindObserver 70 (plus Heater
power)
15mA + 55mA at 12v WindMaster/WindMaster Pro
Input voltage (SDI-12)
9.6v to 16v dc (12v nominal)
Current
6.1mA +9mA at 12v with a WindSonic Option 2
6.1mA +9mA at 12v with a WindSonic M (plus heater
power)
6.1A + 50mA at 12v with a WindObserver 70 (plus
heater power)
SDI-12 not applicable with WindMaster/Pro