MetPak Base Station User Manual
©
Gill Instruments Ltd
Last Change
Page iv
22 April, 2013
6.2
MetPak Base Station Hub
PCB Connections
The following tables summarise the connections for:
HygroClip
WindSonic anemometer
RS232/RS422/RS485/SDI-12 communications. Connection details are
also found within the MetPak Base Station Hub box.
Factory Connections
Table 13
HygroClip connections (6-way connector J1)
Connector J1
Wire Colour
Signal Name
1
-
No Connection
2
Blue
RXD from HygroClip UART
3
Red
TXD to HygroClip UART
4
Yellow
Analogue 0V (Not Used)
5
Grey
Supply-ve /Signal 0V
6
Green
ve (+3.3V DC)
Table 14
Wind Sensor 10 Metre Cable connections (8-way connector J4)
Connector J4
Wire Colour
Signal Name
1
Brown/White
Anemometer Output to Hub
2
Blue/White
RS422+ Hub Output to Anemometer
3
White/Brown
RSR422- Anemometer Output to Hub
4
White/Blue
RS422- Hub Output to Anemometer
5
Green/White
Signal Ground
6
White/Orange
Supply –ve
7
-
No Connection
8
Orange White
ve
-
White/Green
Screen to Chassis
User Connections
Table 15
PC communications (8-way connector, J5)
Connector J5
Signal Name
1
SDI-12 TX/RX
2
Signal 0V
3
RS232 TX-
, (or RS422/RS485 TX-) HUB to user
4
RS232 RX-
, (or RS422 RX-) User to HUB
5
RS422 RX+, User to HUB
6
RS422/RS485 TX+, HUB to User
7
Supply 0v
8
ve (12v to 30v dc)