The Reporting Page
can be used to select:-
Report Format
FULL
or USERDEF
Select Parameters to Report
NODE,DIR,SPEED,PRESS,RH,TEMP,DEWPOINT,DIG1,VOLT,STATUS.
Report parameters can be selected in any order or on or off in USERDEF.
The Power Up Page
can be used to select:-
Status Message Output
ON
or OFF.
(
E.g.
METPAK RG OPTION R 2436 VB.39, STARTUP: OK)
Report Message Output
ON
or OFF.
(e.g. NODE,DIR,SPEED,PRESS,RH,TEMP,DEWPOINT,DIG1,VOLT,STATUS,CHECK)
Units Message Output
ON
or OFF
(e.g. -,DEG,MS,HPA,%,C,C,MM,V,-,- DIG1 = CONFIGURED)
The DIG1 Page
can be used to select:-
DIG1 Sensor
ON
or OFF
Sensor Type Should be left selected to
RAIN
Units
MM
or IN
Count can be set from 0.001 to
10.000
in 0.001 unit steps. Should be set to match
the Rain Gauge calibration figure for example 0.199 (mm/hr). This figure can be
found marked on the Rain Gauge internal label.
Substitute Name A field available for typing in a user name between 3 to 8
characters long.
NOTE:
Once all settings have been chosen then save Edited Page Settings to MetPak RG
by clicking on ‘Save Settings to Device’ this will change the MetPak RG
configuration to reflect the new MetSet settings.