Contents
MetPak RG User Manual
©
Gill Instruments Ltd
Last Change
Page 54
12 February, 2013
11. There is a drain hole at the base of the instrument with a gauze covering that might
require periodic cleaning. Carefully lift out the tipping bucket assembly to gain
access to the drain hole for checking/cleaning.
12. Carefully re-assemble the Rain gauge parts. When assembling the funnel to the
base assembly check that the internal funnel does not foul onto the tipping bucket.
This can be checked by pouring in water and checking the bucket tips or if the
whole assembly is not fixed in position by gently rocking the bucket and listening
for the bucket to tip.
13. Internal parts require no lubrication.
NOTES
MetPak RG is supplied with a matching Rain Gauge and its tip calibration factors
will have been pre-programmed into the MetPak hub box. If a replacement or re-
calibrated Rain Gauge is used then the Hub box will need programming using
MetSet with the new tip calibration factor if this has changed.
Calibration figures can be seen on the labels inside the Rain Gauge on the
underneath of the bucket and adjacent to the tip assembly.
5.6
Spare Parts
MetPak RG
1723-10-051
RS232 to USB 1.8M configuration cable.
1723-PK-024
Pressure Sensor Filter Spares kit.
1723-PK-025
Hygroclip Filter Replacement Kit (2 Filters).
1723-PK-076
Aerodynamic Rain Gauge (ARG100/EC (GI).
Rain Gauge
Tipping Bucket Spares Part 1723-PK-114 comprises of:-
3 off nylon screws to retain the bucket to the base assembly.
2 off funnel gauze filters.
2 off funnel gauze retainer top caps.
5.7
Returning the MetPak RG
If a unit has to be returned, it should be carefully packed in the original packaging
and returned to your authorised Gill distributor, with a full description of the fault
condition. An RMA number should be obtained from Gill Instruments first if
returning directly to Gill Instruments.
Drain Hole Gauze