Gill Instruments Limited
_____________________________________________________________________________________________________________
________________________________________________________________________________________________
MetStream 100
Page 5
Issue 2
Doc. No. 1955-PS-001
March 2016
MetStream Power Supply Unit - Part 026-04969
(Supplied with all MetStream Parts 1955-100-0X-XX)
Input Voltage Range
100v to 240V AC @ 300mA max (50/60Hz)
Mains Adaptors
UK, Euro, US and AUS types supplied.
Output Power
Voltage
Regulated 12V DC
±
2%
Current
Up to 1 Amp (over current and short circuit current protected).
DC Cord
1.5 metres long with right angled 2.1 C +ve plug.
Dimensions
Size
79mm long x 55.4mm wide x 37mm deep.
Weight
150 grams.
Materials
External Construction
Plastic, PB free ROHS compliant.
Environmental
Operating temperature
0°C to +40°C
Storage temperature
-20°C to +60°C
Humidity
5% to 95% RH
EMC
BS EN 55024:2010
BS EN 55022:2010
FCC
CFR47 Part 15B
EMI
BS EN55022
FCC (Part 15 Class B)
SAFETY
UL60950-1
MetStream External Protection Box - Part 1955-PK-052
(Supplied with MetStream Part 1955-100-02-XX)
Dimensions
Size
335mm long x 220mm wide x 107mm deep.
Weight
1.5kg
Maximum Cable size
5 x 2.5 mm sq.
Materials
External Construction
Thermoplastic.
Environmental
Moisture protection
IP65
Install Temperature
0°C to +40°C
Operating temperature
-20°C to +70°C