10.1.2
PCI/PCIA Electrical Power Requirements
1)
100Vac - 120Vac, 10VA from a mains supply for the 115V switch position.
2)
200Vac - 250Vac, 10VA from a mains supply for the 230V switch position.
3)
9 - 30Vdc, 55mA from an external low voltage supply for the anemometer (excluding
analogue outputs).
4)
8 - 18Vdc, 50mA max from an external low voltage supply for the interface box only.
3 fuses protect the unit:
1.
Externally accessible
1 A (T) for 115/230v operation.
2.
Internally accessible
500 mA (T) AUX.
3.
Internally accessible
500 mA (T) ANEM.
10.1.3
PCI/PCIA Operation.
There are three Red LED’s on the PCI/PCIA front panel.
When the PCI/PCIA box is powered the Power LED will illuminate.
When a HS is connected as above to the PCI/PCIA box and is set to output continuous data the
box RX LED will flash on/off at the HS output rate thus giving a good indication that the HS output is
wired to the ox correctly and outputting RS422 data correctly.
If the PCI/PCIA RS 232 connection is connected to a computer then when a terminal programme is
opened and commands sent by a PC keypad or program to the box its TX LED will illuminate
intermittently indicating a good connection between the PC and the box. Connector Pin and Cable
Assignments for PCI/PCIA are as follows:-
Anemometer Connector 15 – Way
RS232 Output - 9 way
Pin
Designation
Pin
Designation
1
Screen
1
DCD
2
RS422_RXB (+)
2
TX data
3
RS422_TXB (+)
3
RX data
4
Digital 0V, Signal ground
4
DTR
5
Supply V+
5
Signal Ground
6
Anemometer Sync +
6
DSR
7
Not used
7
RTS
8
Anemometer Sync -
8
CTS
9
RS422_RXA (-)
9
RI
10
RS422_TXA (-)
11
Supply V-
12
Not Used
RS422/Network Input 9 Way
13
Not Used
Pin
Designation
14
Not used
1
Not connected
15
Not Used
2
Not connected
3
Not connected
External, DC Supply 4 - Way
4
RS422_RXA (-)
Pin
Designation
5
Signal ground
1
Interface Box V+
6
RS422_TXA (-)
2
Interface Box V-
7
RS422_TXB (+)
3
Anemometer Only V-
8
RS422_RXB (+)
4
Anemometer Only V+
9
Earth
Sync/Auxiliary Output 9 Way
Pin
Designation
1
Not Used
2
Not Used
3
Not Used
4
Not Used
5
Not Used
6
Anemometer Sync +
7
Anemometer Sync -
8
Not Used
9
Not Used
External D.C. Supply Amphenol C91A
Screw Lock 4 Way Socket, e.g. T3301 001.
View looking at pins
1
4
3
2
Summary of Contents for 1199-PK-085