Hydraulic System
334
Possible Cause
Remedy
Problem: Hydraulic fluid discolored or smells bad
Check and correct cause for overheating. Look
for restrictions.
A. Operating temperatures high
Increase fluid inspection/change frequency.
B. Fluid change intervals too long
Drain, flush, and refill with proper fluid.
C. Incorrect fluid used
Possible Cause
Remedy
Problem: High operating temperature
Check back pressure.
A. Fluid flow restriction
Check maximum fluid flow.
B. Fluid flow too high
Possible Cause
Remedy
Problem: Foaming hydraulic fluid in reservoir
See pump servicing instructions.
A. Air leak in suction side of pump
Check for restrictions in pump supply.
B. Pump cavitating
See “High operating temperature,” above.
C. Fluid overheating
Change to correct fluid.
D. Incorrect fluid
Possible Cause
Remedy
Problem: Excessive pump pressure with steering gear in neutral position
Relocate return line.
A. Pinched return line
Repair steering column.
B. Binding steering column
Replaced damaged parts.
C. Damaged actuating shaft bearing
Summary of Contents for LOW FLOOR
Page 18: ...Specifications 18...
Page 58: ...Preventive Maintenance 58...
Page 110: ...Engine 110...
Page 138: ...Transmission Driveline Rear Axle 138...
Page 182: ...Suspension 182...
Page 260: ...Air System 260...
Page 420: ...Electrical System 420 Deutsch DT Series Connectors...
Page 421: ...Electrical System 421...
Page 422: ...Electrical System 422 Deutsch HD 10 Series Connectors...
Page 423: ...Electrical System 423...
Page 424: ...Electrical System 424 Deutsch HD 30 Series Connectors...
Page 425: ...Electrical System 425...
Page 442: ...Heating Air Conditioning 442...
Page 492: ...Body and Interior 492 Figure 11 33 USSC Seat Assembly...
Page 493: ...Body and Interior 493 Figure 11 34 USSC Seat Suspension Assembly...
Page 495: ...Body and Interior 495 Figure 11 37 Seat Air Connections...