Accessories:

Chapter 4 
HOW TO USE

4.1 Assembly

1.  Remove all packages

 Attention: 

For the first time of use, please clean and 

disinfect the device before use.

2.  Assembly of nebulizer

1)  Install medication cup to the main unit by pushing 

it towards the main unit. 

  Attention: When installing medication cup to the 

main unit, be sure to install it properly until clasp 

sound is heard. Otherwise it may cause electrode 

conduction failure, then the device cannot atomize 

normally.

2) Remove  medication  cup  from  main  unit.  Press 

and  hold  the  "PUSH"  button  on  main  unit,  and 

push medication cup away from the main unit.

  Attention: In order to avoid device damage, 

please press the "PUSH" button first when remov-

ing medication cup.

Adult mask

The power adapters (optional)

Child mask

Push away

PUSH Button

ENGLISH

Push

Summary of Contents for 28066

Page 1: ...TTENTION The operators must carefully read and completely understand the present manual before using the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le produ...

Page 2: ...thetic mixture Otherwise it may cause personal injury Do not wrap the power cord around children s neck or other sensitive areas or it may cause asphyxia The mask of this equipment is made of PVC mate...

Page 3: ...batteries is DC3V 2 3 Operational environment Temperature 5 C 40 C Humidity 15 90 Atmospheric pressure 700hPa 1060hPa Attention This product is not suitable for use in strong electromagnetic interfer...

Page 4: ...cup to the main unit be sure to install it properly until clasp sound is heard Otherwise it may cause electrode conduction failure then the device cannot atomize normally 2 Remove medication cup from...

Page 5: ...ery life will be affected Remove the batteries if the device won t be used for long time 4 2 Operations for treatment use Preparations before use 1 Remove medication cup please clean and disin fect it...

Page 6: ...the cup lid and discard residual medication 3 Add 75 ethanol solution in medication cup cover the cup lid then leave for at least 10mins it is advisable to gently shake it for better disinfection 4 Im...

Page 7: ...medication cup Trickle medication into medication cup re member not to exceed its maximum capacity Improper medication Consult a doctor about whether the medica tion is suitable for the device The ne...

Page 8: ...ode Keep away from sunlight 55 C 40 C Store between 40 and 55 C Lot number Fragile handle with care Date of manufacture Serial number Follow instructions for use Medical Device complies with Directive...

Page 9: ...4 2 Air Discharge 2 kV 4 kV 8 kV 15 kV contact 8 kV air Air Discharge 2 kV 4kV 8 kV 15 kV contact 8 kV air Floors should be wood concrete or ce ramic tile If floor is covered with synthetic material...

Page 10: ...ct was purchased If the equipment is not disposed of correctly fines or penalties may be applied in accordance with the national legislation and regulations GIMA WARRANTY CONDITIONS Congratulations fo...

Reviews: