Connecting controllers in parallel
9: Connecting controllers in parallel
o
Connect controller and optional installation button according to connection diagram ( 9).
5.2 Commissioning
Checking the detection area
o
Switch on test operation ( 4. Operation).
o
Pace off the detection area, paying attention to reliable detection and interference sources.
o
If necessary, limit the detection area to mask out interference sources. To do this, adjust
the sensor head or use a cover plate ( 4. Operation).
Making operation settings
For detailed information, see the chapter Operation ( 4. Operation).
o
Switch on automatic mode.
o
Set brightness threshold.
o
Set follow-up time.
6 Appendix
6.1 Technical data
Rated voltage
AC 230 V ~
Mains frequency
50 Hz
Power consumption
approx. 1.3 W
Ambient temperature
-35 ... 50 °C
Protection rating
IP 54
Circuit breaker
max. 10 A
Installation height
2.5 m
Detection angle
approx. 110 °
Range
approx. 16 m
run-on time
approx. 12 s ... 12 min
Follow-up time (test)
approx. 1 s
Lockout time
approx. 2 s
Brightness setting
approx. 5 ... 300 lx (and day operation)
Connected load
Incandescent lamps
2200 W
HV halogen lamps
1000 W
Tronic transformers
Type-dependent
82508412
19.05.2011
8/10
Observer 110