Configuration in the ETS
Order No. 2089 00
Page 24
7.5.2. Parameter page Time server
The parameter page Time server is only visible when the timer server is activated on the parameter
page General.
Remote access for the
“residents” or
“installer” groups after
restart
as before restart
After a restart, the remote access status of the
respective group is set to the last known value
before the restart. For example, if the remote
access status is activated before the restart, the
remote access status is also activated after a
restart.
activated
Enables remote access for the respective group
after each restart.
deactivated
Prohibits remote access for the respective group
after each restart.
Number of notification
objects
0
...50
Specify the number of notification objects here
(max. 50).
The “101 ff.” group objects are visible according to
your selection.
Separator for floating
point numbers
.
,
Parameters
Entry / Selection
Remarks
Send time
every minute
every hour
every day
The interval for sending the time to the bus is con
-
figured with this parameter.
Send date
every minute
every hour
every day
The interval for sending the date to the bus is con
-
figured with this parameter.
Parameters
Entry / Selection
Remarks