For your safety

Serious injury e.g. caused by an electric 
shock, fire, or material damage are possible 
in case of improper assembly. Read and 
observe these instructions completely.

Product features

The smoke alarm device Dual Q is a battery-
operated combination of smoke and heat 
alarm device for private residential units or 
similarly inhabited areas as per DIN 14676.
The smoke alarm device Dual Q detects the 
development of smoke in a timely manner 
and warns occupants before the smoke gas 
concentration becomes dangerous. The 
warning comes in the form of acoustic 
(tone) and optical (LED) signals. 
• Loud, pulsating alarm signal

(at least 85 dB (A)).

• Fire and heat alarms alerted differently.
• Muffled alarm signal (approx. 75 dB (A))

during function test.

• Smoke detection by photoelectric

scattering principle.

• Heat detection via maximum and

differential function.

• Integrated function button for alarm

acknowledgement, function test and
muting, for example.

• Smoke detection can be switched off.
• Automatic smoke evaluation self-test

with tracking of soiling.

• "Fouling/malfunction" indication.
• Signalling of technical faults can be

delayed up to 12 h in darkness.

• Up to 40 smoke alarm devices can be

networked on each wire.

Electrical devices may only be 
installed and connected by a 
qualified electrician! 

Configuration and installation may 
only be performed by an expert

As per DIN 14676, configuration, installation 
and maintenance of the smoke alarm device 
may only be performed by a qualified expert. 
For this purpose, Gira offers the "Certified 
expert for smoke alarm devices in accor

-

dance with DIN EN 14676" online course, 
complete with certificate. 
More detailed information can be found 
under "akademie.gira.de".

• One module interface for three optional

modules with simultaneous use of the
networking terminal

• Meets requirements of the new Q Label

quality seal

Q Label means

• Tested longevity of the smoke alarm

device (up to 10 years after activation)

• Fewer false alarms
• Increased stability, e.g. against external

factors

• Permanently installed, non-removable

battery

Scope of delivery

• 1x smoke alarm device Dual Q
• 1x set of mounting hardware
• 1x assembly and operating instructions

Accessories

The following optional accessories can be 
used:
• Relay module for smoke alarm

device Dual (item no. 2340 00)

• Radio module for smoke alarm device

Dual
(item no. 2347 00) 

• KNX Module for smoke alarm device

Dual
(item no. 2343 00) 

• Spacer sleeves (item no. 2342 00)

Device description

Selecting the installation location

When selecting the installation location for 
the smoke alarm device, the specifications 
of DIN 14676 apply. The most important 
specifications are as follows:
• Attach as close as possible to the centre

of the ceiling (min. distance of 50 cm
from walls, lights and other obstructions)

• One smoke alarm device per room (max.

60 m

2

 area)

• Do not mount it in the direct proximity of

heat sources.

1 Mounting plate
2 Module interface
3 Smoke penetration openings
4 Function button
5 Ring indicator
6 Battery
7 230 V connection for power supply via 

230 V base

1

4

5

2

7
6

3

Minimum protection/optimum protec

-

tion

The following applies to flats and houses:

Minimum protection

• One smoke alarm device in every

bedroom, every child's room and in the
hallway/staircase (escape route).

• In the case of open connections across

two levels, a smoke alarm device is to be
mounted at the highest level.

• In the case of buildings spanning several

floors, a smoke alarm device must be
mounted on each floor.

Optimum protection

• One smoke alarm device per room and

floor

• In the case of larger buildings, use

networked smoke alarm devices

• Use specialised alarm devices (e.g. heat

detectors) in sensitive areas such as 
kitchens, garages etc.

Wiring smoke alarm devices

A maximum of 40 Dual Q smoke alarm 
devices can be networked together using a 
two-core cable (e.g. telephone cable J-
Y(St)Y 2 x 2 x 0.6 mm). This enables an 
alarm to be triggered over all the smoke 
alarm devices in a residential unit at the 
same time. 
The maximum cable length varies 
depending on the cable type and cross-
section used (for 1.5 mm

2

 = maximum 400 

m).
Network the smoke alarm devices with one 
another as follows:
1. Remove the pre-perforated cut-out for

the cable inlet from the mounting plate
with a suitable tool.

2. Wire the two-lead cable to the 3-pole

terminal block.

3. Push the terminal block onto the guide

rail of the bracket (will audibly engage).

System description of smoke alarm 

devices

More detailed information with regard to ins

-

tallation as per DIN

 

14676 can be found in 

the "System description of smoke alarm devi

-

ces", which is available in the Gira download 
area (www.gira/download).

Inadmissible installation locations

The Dual Q smoke alarm device is 

not

 suita

-

ble for installation in caravans, campers, 
boats etc.

Deceptive alarms

Some sites are unsuitable for the 
installation of a smoke alarm device as 
deceptive alarms are repeatedly triggered 
due to local conditions (e.g. welding/
soldering work, very heavy water/cooking 
vapour and similar fumes). 
More detailed information with regard to 
unsuitable installation sites can be found in 
the "System description of smoke alarm 
devices".

Deactivating smoke detection

Optionally, smoke detection of the smoke 
alarm device can be deactivated. This 
enables the smoke alarm device to also be 
used in rooms which are unsuitable for 
conventional smoke alarm devices. In this 
case, the smoke alarm device only operates 
as a heat detector and triggers an alarm 
• As soon as the speed at which the

ambient air is heating up lies outside
normal parameters.

• If the ambient temperature is over

+54 °C.

Smoke detection can be deactivated as 
follows:
1. Break out the DIP switch cover plate

with a suitable tool.

2. Set the DIP switches to the "ON"

position. Smoke detection is now
deactivated, and only heat detection is
active.

Installing the smoke alarm device

1. Install the mounting plate. For "surface-

mounted installation" of the networking
cable, use the spacer sleeves.

Optional: Before installation, you can 
activate theft protection of the smoke alarm 
device to impede unauthorised removal of 
or tampering with the smoke alarm device.
For this purpose, cut out the pre-perforated 
cut-out on the housing of the smoke alarm 
device with a suitable tool. The lock can 
only be opened with a tool when in the 
locked state.

Networking terminal

An external button (e.g. emergency switch) 
can also be connected in parallel via the net

-

working terminal.

Termination of CE conformity

The CE conformity of the smoke alarm device 
as per EN 14604 is terminated if the DIP 
switch cover plate is broken out.

Click

N

N

2. Lock the smoke alarm device on the

mounting plate (set in place and turn
clockwise).
Removal is carried out in the reverse
order (turn anti-clockwise and pull off).

3. Wait for the initialisation phase (approx.

30 s) and then carry out the function test
(see "Function test").

Activation/deactivation

The smoke alarm device features an internal 
activation button (grey).

When locking the smoke alarm device into 
the mounting plate/230 V base, the smoke 
alarm device is activated automatically.
Alternatively, the activation button for the 
function test can also be held manually (the 
power supply of the smoke alarm device is 
activated automatically. Initialisation phase 
30 s).
The smoke alarm device is deactivated 
automatically when the lock is disengaged.

Information and 
recommendations for the expert

Declaration of performance

The Declaration of performance according 
to Directive (EC) No. 765/2008, Directive 
(EU) No. 305/2011 (Construction Products' 
Regulations - CPR) and the Construction 
Product Act CPA can be found either in the 
download area (gira.de/Konformitaet) or 
directly via the online catalogue at the 
product (katalog.gira.de).

Briefing and transfer

Maintenance book for smoke 

alarm devices

Gira offers the "Maintenance book for smoke 
alarm devices" in the download area.
All the important data of the initial installa

-

tion of the smoke alarm device should be 
entered here.

Briefing and transfer of the 

Instructions

Explain all the functions of the product to 
the end user or their representative.
These instructions are part of the product 
and must be transferred to the end user or 
their representative for safekeeping.

Technical data

Type of alarm:

Optical smoke alarm 
and heat detector

Area of application:

Inside (ceiling)

Installation in 
recreational vehicles, 
motor homes, etc:

Not suitable!

Power
supply:

via the smoke alarm 
device battery 
(encapsulated, not 
replaceable)
In addition, AC 230 
V when using item 
no. 2331 02 

Battery life:

up to 10 years (after 
activation)

Acoustic signal:

Alarm: at least 85 dB 
(A)
Test: approx. 75 dB 
(A)

Optical indication:

Ring indicator (red 
LED) indicates 
status and faults

Networking:

Wired, with modules

Integrated interface:

For KNX module, 
wireless module and 
relay module

Function key for:

Function test
Muting
Alarm 
acknowledgement
Delaying "fault" 
display

Ambient 
temperature:

-5 °C to +55 °C

Storage 
temperature:

-20 °C to +65 °C

Transport 
temperature:

-20 °C to +65 °C

Installation height:

Max. 6 m

Protection type:

IP 42

Housing dimensions: 125 x 48 mm (dia. x 

h)

Weight:

approx. 250 g

Standards:

DIN EN 14604

RoHS/WEEE-
compliant:

Yes

Environmentally 
compliant disposal:

Governed by EAR

6LE000969 

D

/A 

34

/22

Dual Q smoke alarm 
device

23

46 

02

Assembly and operating instructions

en

Summary of Contents for 2346 02

Page 1: ...ple Heat detection via maximum and differential function Integrated function button for alarm acknowledgement function test and muting for example Smoke detection can be switched off Automatic smoke e...

Page 2: ...tem no 2340 00 Radio module for smoke alarm device Dual item no 2347 00 KNX Module for smoke alarm device Dual item no 2343 00 Spacer sleeves item no 2342 00 Device description Selecting the installat...

Page 3: ...length varies depending on the cable type and cross section used for 1 5 mm2 maximum 400 m Network the smoke alarm devices with one another as follows 1 Remove the pre perforated cut out for the cable...

Page 4: ...deactivated and only heat detection is active Installing the smoke alarm device 1 Install the mounting plate For surface mounted installation of the networking cable use the spacer sleeves Optional B...

Page 5: ...matically when the lock is disengaged Information and recommendations for the expert Declaration of performance The Declaration of performance according to Directive EC No 765 2008 Directive EU No 305...

Page 6: ...Test approx 75 dB A Optical indication Ring indicator red LED indicates status and faults Networking Wired with modules Integrated interface For KNX module wireless module and relay module Function ke...

Page 7: ...until the signal tone is muted and the ring indicator goes out Muffled signal tone The signal tone of the function test is muffled approx 75 dB A This is intended to prevent hearing loss e g tinnitus...

Page 8: ...g signal tone flashes quickly Local heat alarm 8 brief signal tones in 60 s cycle Flashes 8 times in 8 s cycle Fault 2 brief signal tones in 60 s cycle Flashes once in 5 s cycle Weak battery 1 s long...

Page 9: ...arning up to 12 hours in darkness This does not affect the functionality of the smoke alarm device The message can be delayed by 8 hours at a time for a maximum of 7 days if the initial signalling occ...

Page 10: ...rm device must always be disposed of completely Battery life The battery life approx 10 years after activation can be reduced by the following factors The additional use of modules Networking of the s...

Page 11: ...ssessments More detailed information on this can be found in the System description of smoke alarm devices or in DIN EN 14676 The following always applies Always protect yourself first Warn other occu...

Page 12: ...Gira Gira Giersiepen GmbH Co KG Elektro Installations Systeme P O Box 1220 42461 Radevormwald Germany Phone 49 2195 602 0 Fax 49 2195 602 191 info gira de www gira de...

Reviews: