background image

Function button

The smoke alarm device Dual Q features an 
easy-access main function button.

The following actions can be initiated using 
the function button (grey) in normal 
operation:
• Alarm acknowledgement
• Function test
• Muting
• Delaying fault/soiling display

Function test

The function test should be conducted:
• After the initial installation
• After every alarm, maintenance session 

and fault message

Perform the function test

Carry out the function test as follows:
1. Press and hold the function button for 

approx. 4 s. Initially, a brief 
acknowledgement tone can be heard. A 
muffled signal tone is then emitted, and 
the ring indicator flashes. 

2. Release the function button.
3. If the function test was successful: Press 

and hold the function button until the 
signal tone is muted and the ring 
indicator goes out.

Muffled signal tone

The signal tone of the function test is 
muffled (approx. 75 dB (A)). This is 
intended to prevent hearing loss (e.g. 
tinnitus).

Function test failure

Replace the smoke alarm device immediately 
if it fails the function test two times in a row. 
Non-operational smoke alarm devices may 
not be installed.

Function test for wire-networked 

smoke alarm devices

When a function test is carried out on wire-
networked smoke alarm devices, all the con

-

nected smoke alarm devices emit only an 
acoustic alarm. If this is not the case, check 
the connections and networking lines.

Smoke alarm devices save lives

Observe the following when using smoke 
alarm devices:
• Use only smoke alarm devices which 

are compliant with DIN 14604

• Never cover smoke alarm devices 

continuously or block them with objects

• Never install smoke alarm devices if 

they are defective or not fully 
operational

Operating and alarm signals

Local smoke alarm device

* Replace alarm device within 30 days.

Networked smoke alarm device

In the case of wired networking, signalling 
occurs at the triggering smoke alarm device 
as described above. The networked smoke 
alarm devices signal as follows:

* Replace alarm device within 30 days.

Acknowledging alarm/deceptive 
alarm

If the smoke alarm device has triggered an 
alarm and a deceptive alarm has been 
identified as the culprit, you can 
acknowledge the alarm message by 
pressing the function button. Then ensure 
that the cause of the deceptive alarm has 
been eliminated. Should this be temporarily 
impossible, activate muting if necessary.

Signal tone

Ring 
indicator

Meaning

        -

       -

Operating 
mode

Loud interval 
tone

flashes 
quickly

Local smoke 
alarm

Loud 
pulsating 
signal tone 

flashes 
quickly

Local heat 
alarm

8 brief signal 
tones in 60 s 
cycle

Flashes 8 
times in 8 s 
cycle

Fault

2 brief signal 
tones in 60 s 
cycle

Flashes 
once in 5 s 
cycle

Weak battery*

1 s-long 
signal tone in 
2 s cycle

Lights up 
continuousl
y

Function test 
(alarm device 
has triggered 
alarm)

1 s-long 
signal tone in 
2 s cycle

flashes 
quickly

Function test 
(alarm device 
has not 
triggered 
alarm)

        

 -

Flashes in 
2 s cycle

Muting

Brief signal 
tone in 1 s 
cycle

Flashes in 
1 s cycle

EMC fault

Brief signal 
tone in 250 
ms cycle

Flashes for 
5 min in 250 
ms cycle

Identification 
of alarm device

Signal tone

Ring 
indicator

Meaning

Loud 
interval 
tone

 
       -

Smoke or heat 
alarm message

1 s-long 
signal tone 
in 2 s cycle

       -

Function test 
(remote starting)

2 brief 
signal tones 
in 60 s cycle

       -

Weak battery*

Signalling when using the 230 V 

base

When using the 230 V socket, the 
signalling differs.
Please observe the installation and 
operating instructions for the 230 V base 
for Dual Q smoke alarm devices. 

Activating muting

The smoke alarm device features so-called 
"muting".
It deactivates smoke alarm device operation 
for a maximum of 15 min. This makes sense
• As a measure to prevent deceptive 

alarms, e.g. while engaged in activities 
which create a large amount of dust 
(sweeping a dusty room, sweeping the 
chimney etc.) or 

• to stop an alarm triggered by the 

detection of harmless smoke (e.g. when 
searing meat)

Activate muting as follows:
1. Press the function button for 1 s until 

the acknowledgement tone is heard.

2. Release the function button: The ring 

indicator flashes in a 2 s cycle, and 
muting is activated.

After 15 minutes, muting is automatically 
deactivated and the smoke alarm device is 
back in the normal operating mode.

Delay fault/soiling indication

The photocell integrated in the smoke alarm 
device delays the "Smoke alarm device 
soiled" warning up to 12 hours in darkness. 
This does not affect the functionality of the 
smoke alarm device!
The message can be delayed by 8 hours at a 
time for a maximum of 7 days if the initial 
signalling occurs at an unfavourable point in 
time. 
For this purpose, push the function button 
until the first signal tone to sound is muted. 
The "Fault/soiling" message is now 
signalled after a delay.

Care and maintenance

Clean and maintain the smoke alarm device 
on a regular basis to ensure full operability.

Care 

Wipe the smoke alarm device with a moist 
(not wet!) cloth on a regular basis. 
The smoke alarm device can also be cleaned 
of dust carefully with a vacuum cleaner 
(lowest setting).

Maintenance

Maintenance and duty to maintain

As per DIN 14676, you are required to have 
smoke alarm devices maintained annually 
by a qualified expert.
The results of maintenance should be 
entered in the maintenance book for 
smoke alarm devices.
Observe the following: If this required 
maintenance is not carried out, insurance 
coverage may be nullified in case of fire. 

Renovation work

Disposal

Dispose of the smoke alarm device by the 
date indicated on the device's label or when 
the battery is flat.

Troubleshooting

Renovation work

If possible, do not install the smoke alarm 
device until all renovation work has been 
completed. Should this not be possible, 
cover the smoke alarm device with the 
included covering cap (remove it again 
once the work is complete!). Alternatively, 
you can remove the smoke alarm device 
for the duration of the work. Once the work 
is complete, the original functional 
readiness of the installed smoke alarm 
device must be restored and tested 
(function test). 

Danger
There is a risk of explosion if the 
battery is removed by force!

The battery of the smoke alarm device 

cannot

 be replaced.

If the battery is forcibly removed from the 
device, it may explode if damaged.
The smoke alarm device must always be 
disposed of completely. 

Battery life

The battery life (approx. 10 years after 
activation) can be reduced by the following 
factors:
• The additional use of modules.
• Networking of the smoke alarm devices 

via networking terminal.

• More test alarms than prescribed.

The Gira smoke alarm device is 
an electric and electronic device 
in the sense of EU guideline 
2002/96/EC.
The device was developed and 
manufactured using high-quality 
materials and components. 
These materials and components 
can be reused and recycled. 
Please consult the regulations 
governing the separate collec

-

tion of electric/electronic waste 
applicable for your country. 
These devices may not be dispo

-

sed of with household waste. 
The correct disposal of waste 
equipment can prevent possible 
negative effects upon humans 
and the environment.

Problem

Solution

No signal can be 
heard during the 
function test

Check locking of the 
smoke alarm device

Frequent 
deceptive alarms

Check installation site 
for interference 
sources
Cleaning smoke alarm 
device

Warranty

The warranty is provided in accordance with 
the statutory requirements via the retailer.
Please hand over or send faulty devices 
postage paid and with a description of the 
problem to your sales representative 
(retailer / installation company / electronics 
retailer),
They will forward the devices to the Gira 
Service Centre.

Information and 
recommendations for occupants

Response in case of fire

To facilitate a proper response by the 
persons concerned in case of fire, 
DIN 14676 recommends putting up 
information in every unit on how to respond 
in case of fire. This information should be 
provided in the languages which are 
commonly used, You may also need to take 
the end users of a residential unit into 
consideration (e.g. non-German speakers). 
The standard also strongly recommends 
calling in a responsible fire prevention 
authority in advance. This authority can 
define divergent or different 
recommendations or assessments.
More detailed information on this can be 
found in the "System description of smoke 
alarm devices" or in DIN EN 14676.

The following always applies:

• Always protect yourself first!
• Warn other occupants.
• Leave the room/building immediately.
• Help people in need while escaping.
• In case of thick smoke, keep low to the 

ground.

• Check whether all persons have left the 

room/building.

• Should you not be able to leave the room/

building, close all doors and seal all gaps 
and other narrow openings, e.g. with wet 
towels. Alert people to your presence 
from the window.

• Do not call the fire brigade until you are 

safe.

• Only fight the fire yourself if you will not 

be putting yourself in danger.

Q label and warranty

The Q label has no effect on the legal 
warranty. 

Warning function of the 

smoke alarm device

The sole purpose of the warning function 
of a smoke alarm device is to warn the 
people present in a unit (e.g. flat) or 
building in a timely manner. The people 
present organise their rescue themselves 
and are responsible for notifying the 
station providing assistance (e.g. fire 
brigade).

Smoke alarm devices do not extinguish 
fires!

Gira

Gira
Giersiepen GmbH & Co KG
Elektro-Installations-Systeme
P.O. Box 1220
42461 Radevormwald, Germany
Phone: +49 2195 602 - 0
Fax: +49 2195 602 - 191
info@gira.de
www.gira.de

Summary of Contents for 2346 02

Page 1: ...ple Heat detection via maximum and differential function Integrated function button for alarm acknowledgement function test and muting for example Smoke detection can be switched off Automatic smoke e...

Page 2: ...tem no 2340 00 Radio module for smoke alarm device Dual item no 2347 00 KNX Module for smoke alarm device Dual item no 2343 00 Spacer sleeves item no 2342 00 Device description Selecting the installat...

Page 3: ...length varies depending on the cable type and cross section used for 1 5 mm2 maximum 400 m Network the smoke alarm devices with one another as follows 1 Remove the pre perforated cut out for the cable...

Page 4: ...deactivated and only heat detection is active Installing the smoke alarm device 1 Install the mounting plate For surface mounted installation of the networking cable use the spacer sleeves Optional B...

Page 5: ...matically when the lock is disengaged Information and recommendations for the expert Declaration of performance The Declaration of performance according to Directive EC No 765 2008 Directive EU No 305...

Page 6: ...Test approx 75 dB A Optical indication Ring indicator red LED indicates status and faults Networking Wired with modules Integrated interface For KNX module wireless module and relay module Function ke...

Page 7: ...until the signal tone is muted and the ring indicator goes out Muffled signal tone The signal tone of the function test is muffled approx 75 dB A This is intended to prevent hearing loss e g tinnitus...

Page 8: ...g signal tone flashes quickly Local heat alarm 8 brief signal tones in 60 s cycle Flashes 8 times in 8 s cycle Fault 2 brief signal tones in 60 s cycle Flashes once in 5 s cycle Weak battery 1 s long...

Page 9: ...arning up to 12 hours in darkness This does not affect the functionality of the smoke alarm device The message can be delayed by 8 hours at a time for a maximum of 7 days if the initial signalling occ...

Page 10: ...rm device must always be disposed of completely Battery life The battery life approx 10 years after activation can be reduced by the following factors The additional use of modules Networking of the s...

Page 11: ...ssessments More detailed information on this can be found in the System description of smoke alarm devices or in DIN EN 14676 The following always applies Always protect yourself first Warn other occu...

Page 12: ...Gira Gira Giersiepen GmbH Co KG Elektro Installations Systeme P O Box 1220 42461 Radevormwald Germany Phone 49 2195 602 0 Fax 49 2195 602 191 info gira de www gira de...

Reviews: