System 3000

speed regulator insert

5

Information for electrically skilled persons

5.1 Fitting and electrical connection

 DANGER!

Mortal danger of electric shock.

Disconnect the device. Cover up live parts.

Fitting and electrical connection

L

1

N

16 A

AC 230 V ~

L

M

L

I

max

 = 1,8 A

N

1

1

N

L

~

(4)

(2)

(1)

(5)

(6)

(3)

Figure 1: Connection diagram with optional extensions

(1)

Button Test

(2)

LED display

(3)

Rotary axle

(4)

3-wire rotary extension

(5)

2-wire extension

(6)

Push-button, NO contact

The connection of a central extension is not possible.

Operation without neutral conductor possible.

Only connect illuminated push buttons if they have a separate N terminal.

Precondition: The maximum motor current (I

max

) must not exceed the switching current of 1.8 A.

2 / 5

82404702

01.04.2021

Summary of Contents for System 3000 2460 00

Page 1: ...tion with suitable cover 3 Product characteristics Product characteristics Device is operating in leading edge phase control Operation without neutral conductor possible Switch on via soft start to maximum speed Minimum speed can be saved permanently Connection of extensions possible Electronic short circuit protection with permanent switch off after approx 100 ms Electronic over temperature prote...

Page 2: ...N 1 1 N L 4 2 1 5 6 3 Figure 1 Connection diagram with optional extensions 1 Button Test 2 LED display 3 Rotary axle 4 3 wire rotary extension 5 2 wire extension 6 Push button NO contact The connection of a central extension is not possible Operation without neutral conductor possible Only connect illuminated push buttons if they have a separate N terminal Precondition The maximum motor current Im...

Page 3: ...insulated tools for the work Cover up live parts in the working environ ment The minimum speed must be set so that the motor does not stop at the lowest speed set ting Prerequisites Speed controller is ready for operation and the central plate is not mounted Press the button Test 1 until LED 2 lights up The current operating state remains the same After 45 seconds without an actuation the LED 2 go...

Page 4: ... 1 overheating protection has tripped Reduce the connected load Disconnect the speed controller from the mains by switching off the circuit breaker Let the speed controller cool down for at least 15 minutes Switch on the circuit breaker and speed controller again Cause 2 short circuit protection has tripped Disconnect the speed controller from the mains by switching off the circuit breaker Elimina...