Troubleshooting
45
Code no. 576074
Rev. nº 03/0418
7 INVERTER CONFIGURATION FAULT
Lack of concordance between the inverter operating settings and the microprocessor memory settings.
Probable cause:
Inverter not initialised.
Accidental modification or loss of the inverter configuration settings.
Procedure:
Disconnect the power supply from the machine and reconnect after five minutes.
If fault persists or is frequently repeated, contact Technical Assistance Service.
8 LINT DOOR OPEN
Indication that the door of the protective filter is open in a closed filter door situation or while a program is
running.
Probable cause:
Poorly closed filter door.
Fault in the system detecting the condition of the door.
Procedure:
Disconnect the power from the machine and check that the door is properly closed and that there is no
blockage preventing the door from closing properly.
If the problem is not resolved or recurs frequently, contact the Authorised Technical Service.
9 OVER TEMPERATURE
Over-temperature detected by the machine’s output control.
Probable cause:
Fault in the output temperature control system.
Fault in the machine’s individual temperature controls.
Procedure:
Disconnect the power supply and contact Authorised Technical Services.
In dryers with gas heating, close the manual gas inlet valve.
10 HEATING FAULT
The dryer does not detect the increase in the internal temperature when the heating system is on.
Probable cause:
Fault in the heating system.
Fault in the internal temperature detection system.
Procedure:
Disconnect the power supply from the machine and reconnect after five minutes.
If fault persists or is frequently repeated, disconnect the power supply and contact your Authorised Technical
Service.
In dryers with gas heating, close the manual gas inlet valve.