Technical data
42
Code no. 550038
Rev. no. 16/1018
Propane
G31
Supply pressure
mbar
50
50
50
(in.wc)
(20.7)
(20.7)
(20.7)
Massic consumption
kg/h
3.54
4.53
6.15
(lb/h)
(7.81)
(9.99)
(13.57)
Nominal calorie cons. with
regard to H
i
kW
46.8
59.8
80.8
(BTU/h)
(159688)
(204046)
(275701)
Nominal calorie cons. with
regard to H
s
kW
50.9
65.0
87.8
(BTU/h)
(173570)
(221784)
(299668)
Injector diameter
mm
27
31
42.8
Solenoid valve adjustm.
(See Figure 5.12).
mm
6
5
4.5
RADIANT BURNER 60Hz.
MACHINE MODEL
Combustible gases circuit:
type B13
in accordance with EN1020
(Append. B)
UNITS
PB/PBP5119
PB/PBP5125
PB/PBP5132
Natural
G20
Supply pressure
mbar
20
20
20
(in.wc)
(8.03)
(8.03)
(8.03)
Volumetric consumption
m
3
/h
5.06
6.48
8.6
(cu.ft/h)
(178.7)
(228.8)
(302.3)
Nominal calorie cons.
with regard to H
i
kW
46.9
60.1
80.9
(BTU/h)
(160029)
(205070)
(276042)
Nominal calorie cons.
with regard to H
s
kW
52.1
66.7
89.8
(BTU/h)
(177716)
(227735)
(306551)
Injector diameter
mm
27
31.5
42
Solenoid valve adjustm.
(See Figure 5.12).
mm
7
7
7
Propane
G31
Supply pressure
mbar
37
37
37
(in.wc)
(14.9)
(14.9)
(14.9)
Massic consumption
kg/h
3.54
4.53
6.15
(lb/h)
(7.81)
(9.99)
(13.57)
Nominal calorie cons.
with regard to H
i
kW
46.8
59.8
80.8
(BTU/h)
(159688)
(204046)
(275701)
Nominal calorie cons.
with regard to H
s
kW
50.9
65.0
87.8
(BTU/h)
(173570)
(221784)
(299668)
Injector diameter
mm
26.5
31
43
Solenoid valve adjustm.
(See Figure 5.12).
mm
6
5
4.5
4.3.3. Maximum NOx values and classification
Maximum NOx values obtained and corrected in accordance with EN1020:2009:
- For 2nd family gases (G20 and G25): 127 mg/kWh. Class 3.
- For 3rd family gases (G31): 155 mg/kWh. Class 2.
4.3.4. Categories of commercially available gases
(Summary of the B1 & B4 tables taken from the EN437:2003+A1:2009 standards)
The specification nameplate identifies the type of gas prepared for the ironer.