Technical data
44
Code no. 550038
Rev. no. 16/1018
4.4.
AGA
certified models.
Specific values for models with GAS heating
Consult the description of the burner in Section 1.2.
VERY IMPORTANT
NOTES RELATING TO POWER AND GAS DETAILS
Volumetric consumptions and massic consumption
. Values calculated at 15ºC (59ºF); 1013 mbar (14.7
PSI).
ATMOSPHERIC BURNER.
AGA
Models
MACHINE MODEL
Combustible gases circuit:
type B14
in accordance with EN1020
(Append. B)
UNITS
PB3215
PB3221
PB/PBP5119 PB/PBP5125 PB/PBP5132
Natural
G20
Supply pressure AGA
mbar
20
20
16
16
16
(in.wc)
(8.03)
(8.03)
(6.4)
(6.4)
(6.4)
Volumetric consumption
m
3
/h
2.42
3.23
4.31
5.60
7.37
(cu.ft/h)
(85.5)
(114.1)
(152.2)
(197.8)
(260.3)
Nominal calorie cons.
with regard to H
i
kW
22.3
30.5
39.9
51.5
69.6
(BTU/h)
(76091)
(104070)
(136144)
(175725)
(237485)
Nominal calorie cons.
with regard to H
s
kW
24.8
33.9
44.3
57.2
77.3
(BTU/h)
(84501)
(115573)
(151192)
(195147)
(263733)
Injector diameter
mm
3.45
4.05
4.70
5.75
6.75
Propane
G31
Supply pressure AGA
mbar
37
37
35
35
35
(in.wc)
(14.85)
(14.85)
(14.1)
(14.1)
(14.1)
Massic consumption
kg/h
1.66
2.51
3.11
3.99
5.43
(lb/h)
(3.66)
(5.54)
(6.87)
(8.80)
(11.96)
Nominal calorie cons.
with regard to H
i
kW
22.0
32.1
41.1
52.6
69.4
(BTU/h)
(75067)
(109554)
140239)
(179479)
(236803)
Nominal calorie cons.
with regard to H
s
kW
23.9
34.9
44.7
57.2
75.4
(BTU/h)
(81593)
(119077)
(152430)
(195081)
(257388)
Injector diameter
mm
2.40
2.75
3.10
3.60
4.15
4.4.1. Maximum NOx values and classification
Maximum NOx values obtained and corrected in accordance with EN1020:2009:
- For 2nd family gases (G20 and G25): 127 mg/kWh. Class 3.
- For 3rd family gases (G31): 155 mg/kWh. Class 2.
4.4.2. Categories of commercially available gases
(Summary of the B1 & B4 tables taken from the EN437:2003+A1:2009 standards)
The specification nameplate identifies the type of gas prepared for the ironer.