Operating and use. Inteli Control
95
Code no. 550038
Rev. no. 16/1018
Roll speed
Speed
control
programmed on the
previous screen.
Unit of speed
selected in the configuration
menu.
Programmable range:
Model
Programmable values
LS
m/min. 1
– 9.0 (min-max)
Ft/min 4
– 29 (min-max)
HS
m/min. 1
– 15.0 (min-max)
Ft/min 4
– 49 (min-max)
Select the desired speed with the
+ / -
keys
.
Press the
OK
key to confirm the selection
and access the next screen.
Caution!
If AUTOMATIC speed control has been programmed on the speed control screen, the value programmed
B
indicates the maximum speed of the rolls.
The speed of the rolls may decrease depending on the difference between the real ironing temperature and the
programmed temperature.
Ironing temperature
Select the ironing temperature using the
+
/
-
keys.
Programmable range
:
Machine with electric/steam heating:
ºC: 70
– 160 (min-max)
ºF: 160
– 320 (min-max)
Machine with gas heating:
ºC 70
– 170 (min-max.)
ºF 160
– 340 (min-max.)
Machines with folder option
The folding mode should be programmed before completing the setting of the program.
See the information regarding the folder in the following section.
End of the programming
Press the
OK
key to save the content of
the program and end the programming.
The
Modification
Tools
screen
is
accessed directly.
Remember that by pressing the
<<,
key the
user can access previous screens and
modify the program.