18
Girbau, SA
113432-1
Electric Models Only
All electrically heated dryers must be connected to the electric
service shown on the dryer’s data label. The connecting
wires must be properly sized to handle the rated current.
1/25/06
Warning (Gas Models Only)
Dryers built for use with a voltage between 200
and 240 must verify the input voltage during
installation. If the nominal voltage is outside of the
medium tolerances shown on the diagram below, adjust
the autotransformer, located near the burner assembly. To
adjust the autotransformer wiring, place the red wire on the
appropriate tap (HIGH, MED, LOW) of the autotransformer.
For additional wiring details, refer to the electrical diagram
located on the inside of the control panel.
Electrical Service Specifications
Gas and Steam Models Only
!
TERM
LINE VOLTAGE
50 Hz
60 Hz
HIGH
260
226
283
249
MED
239
208
260
230
LOW
217
189
236
208
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or
RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National
Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others,
calculate/verify correct breaker size according to appliance amp draw rating and type
of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX. AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
SLI9 Gas
120
1ø
2
8.9
—
15
200
1ø
2
7.7
7.8
15
208
1ø
2
7.6
—
15
220
1ø
2
—
7.4
15
230
1ø
2
—
7.3
15
240
1ø
2
7.2
—
15
SLI14 Gas
120
1ø
2
10.3
—
15
200
1ø
2
8.7
8.8
15
208
1ø
2
8.4
—
15
220
1ø
2
—
8.1
15
230
1ø
2
—
7.8
15
240
1ø
2
7.7
—
15
SLI23 Gas
120
1ø
2
15.6
—
20
200
1ø
2
10.5
—
20
208
1ø
2
10.5
—
20
220
1ø
2
10.0
—
20
240
1ø
2
9.7
—
20
220
1ø
2
—
10.7
20
230
1ø
2
—
10.8
20
SLI23 Steam
120
1ø
2
14.4
—
20
200
1ø
2
8.2
—
20
208
1ø
2
8.2
—
20
220
1ø
2
7.8
—
20
240
1ø
2
7.6
—
20
220
1ø
2
—
8.4
20
230
1ø
2
—
8.5
20
SLI34 Gas
120
1ø
2
15.6
—
20
200
1ø
2
10.5
—
20
208
1ø
2
10.5
—
20
220
1ø
2
10.0
—
20
240
1ø
2
9.7
—
20
220
1ø
2
—
10.7
20
230
1ø
2
—
10.8
20
SLI34 Steam
120
1ø
2
14.4
—
20
200
1ø
2
8.2
—
20
208
1ø
2
8.2
—
20
220
1ø
2
7.8
—
20
240
1ø
2
7.6
—
20
220
1ø
2
—
8.4
20
230
1ø
2
—
8.5
20
1/25/06
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5
ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical
Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
OVEN
kW
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
SLI9
200
1ø
2
5.6
32.7
32.7
45
208
1ø
2
4.1
24.2
—
35
208
1ø
2
6.1
34.0
—
45
240
1ø
2
5.4
27.1
—
35
240
1ø
2
8.1
38.4
—
50
208
3ø
3
6.5
22.7
—
30
240
3ø
3
7.5
22.6
—
30
230
1ø
2
5.0
—
26.4
35
230
1ø
2
7.4
—
36.8
50
380
3ø
4
6.8
—
15.0
20
400
3ø
4
7.5
—
15.5
20
416
3ø
4
8.1
—
15.8
20
SLI14
200
1ø
2
12.5
68.0
67.7
90
208
1ø
2
7.9
43.5
—
60
208
1ø
2
13.5
70.4
—
90
240
1ø
2
9.0
42.6
—
60
240
1ø
2
13.5
61.4
—
80
208
3ø
3
13.5
43.0
—
60
240
3ø
3
13.5
37.6
—
50
230
1ø
2
8.3
—
41.3
60
230
1ø
2
12.4
—
59.1
80
380
3ø
4
11.3
—
22.6
30
400
3ø
4
12.4
—
23.1
30
416
3ø
4
13.5
—
23.7
30
SLI23
200
1ø
2
14.8
82.1
—
110
208
1ø
2
16.0
85.1
—
110
220
1ø
2
13.4
68.8
—
90
240
1ø
2
16.0
74.2
—
100
208
3ø
3
16.0
52.6
—
70
220
3ø
3
13.4
43.0
—
60
240
3ø
3
16.0
46.0
—
60
380
3ø
4
13.4
28.0
—
40
220
1ø
2
13.4
—
69.4
90
230
1ø
2
14.7
—
72.3
100
220
3ø
3
13.4
—
43.6
60
230
3ø
3
14.7
—
45.3
60
380
3ø
4
13.4
—
28.6
40
400
3ø
4
14.8
—
29.8
40
416
3ø
4
16.0
—
30.7
40
SLI34
200
1ø
2
20.3
109.8
—
150
208
1ø
2
22.0
113.9
—
150
220
1ø
2
18.5
91.7
—
125
240
1ø
2
22.0
99.2
—
125
208
3ø
3
22.0
69.2
—
90
220
3ø
3
18.5
56.2
—
80
240
3ø
3
22.0
60.4
—
80
380
3ø
4
18.4
35.6
—
45
220
1ø
2
18.5
—
92.3
125
230
1ø
2
20.2
—
96.3
125
220
3ø
3
18.5
—
56.8
80
230
3ø
3
20.2
—
59.1
80
380
3ø
4
18.4
—
36.2
50
400
3ø
4
20.4
—
37.8
50
416
3ø
4
22.0
—
39.1
50
Summary of Contents for SLI14
Page 32: ...Part No 113432 1 01 25 06 0 ...