11
EN
USER’S MANUAL
ACM
Turn On/Off the units
Operator can turn on or off the unit to display or hide the relative weighing units.
INSTANCE
Key (Order)
Step Explanation
LCD Screen Display
Press and Hold
[TARE]&[UNIT] Key for 5
seconds at the same time.
1. When display the menu, enter cod:106
The code of basic setting menu is C00101. The enter way is: Press
[MODE] key to move the digit, press the [TARE] key to circle and set the
number.
C00
1
06
Short Press [UNIT] Key
2. Enter into the menu, display unit: ct and flash ON (turn on)
ct
ON
Short Press [TARE] key.
3. Display unit: ct and FLASH (turn off) (Set OFF/ON with short
press repeatedly)
ct
OFF
Short Press [MODE] key.
4. Enter into Buzzer setting menu, display BEP and flash ON
(turn on)
Short press [TARE] key can select ON (turn on) or OFF (turn off) the
buzzer.
o2
ON
Short Press [TARE] key.
5. Display unit: oz and flash OFF
Repeat the step 4-5 can circle and set follow units: ct, oz, ozt,
lb, dwt, tlT, kg, % .....
The default setting is all units was turn on.
o2
OFF
Short Press [UNIT] key.
6. Set the machine successful and return to the main menu.
C0000
0
Short Press [UNIT] key.
7. Return to standby
NOTE:
The grey color words explain the signal’s meaning wich flash on the window.
VI
SIXTH PART
Machine Weighing Configuration Setting
Purpose
Operator can set the machine basic weighing config to change the weighing capability to reach different required.
Zeroing Range Setting
Operator can increase or decrease tracking range for they need.
Tracking Range Setting
Operator can increase or decrease tracking range for they need.
Sensitivity Level Setting
Operator can adjust the weighing response time by increase or decrease the level. Level 1 is the slowest weighing resopnse speed and level
3 is the fastest (Default and recommend setting: Level 2 )
Speed Level Setting
Operator can adjust the weighing response time by increase or decrease the level. Level 1 is the slowest weighing response speed and level
3 is the fastest (Default and recommend setting: Level 2)
Anti-Vibration level Setting
Operator can adjust the weighing response time and anti-vibration strength by oncrease or decrease the level.
The higher level comes with higher anti-vibration. Level 1 has fast weighing speed and weak anti vibration. Level 7 has strong anti vibration
and low weighing speed.