When mounted at heights above 3 metres there could be 

a significant reduction in the range of detection and the 

target will have to move a greater distance within the field 

of view before an alarm is generated. 

WALK TEST

The range of the detector increase without the front 

protective cover. Therefore the front cover must be fitted 

to establish the correct beam pattern alignment and when 

testing the outputs. Use the programming chart to adjust 

the range as necessary and pan and tilt the lens module 

over the field of view to obtain the correct coverage area.

When the ‘program’ button is pressed momentarily the 

blue indicator lights and pulse count ‘1’ is automatically 

selected. The unit can then be aligned. The blue indicator 

will light on the D-TECT Dual AM every time a detection 

takes place. This test mode will automatically cancel five 

minutes after last detection. Alternatively, remove the 

power and then re-apply. 

OPTION DEFINITIONS

PULSE COUNT 

This is the number of times the unit has to detect on both 

of its sensors before signalling an output. 

LED MONITOR

LED Off - LED disabled.

LED on - LEDs signal a detection.

N/OPEN & N/CLOSED

These are magnetically immune volt free relay contacts 

used to trigger alarm inputs on connected equipment.

The contacts are rated at a maximum of 24 AC/DC @ 

50mA.

ACCESSORIES

GJD is able to supply the following accessories to aid 

installations:

GJD304   Conduit cable entry adaptor ring

GJD305   Pole mount clamp

GJD380   Walk tester

CONNECTING THE UNIT

MULTIBEAM ALIGNMENT & MASKING

The GJD multifunction lens fitted to the D-TECT Dual AM 

detector produces 7 long range beams and 7 medium to 

short range curtain beams. Movement across the beams 

produces the best response and range for the PIRs, 

whilst movement towards the detector produces the best 

response for the microwave sensor. The unit detects 

the changes in heat and movement in the beam pattern, 

therefore items such as trees, shrubs, ponds, boiler flues 

and animals should be considered when positioning the 

detector. 

The detector module is fitted with two sliding shutters to 

reduce the detection angle. An additional set of curtains 

is provided should the beam pattern need to be narrowed 

even further e.g. if the minimum detection angle of 10 

degrees is required.

The curtains are fitted to the pan and tilt module as 

indicated in fig 8. Each section of the detectors lens gives 

a coverage pattern of around 10 degrees. 

When mounting higher than boundary fences rotate the 

module and mask off any beams, vertically or horizontally, 

that fall outside the area being covered. Use portions of 

the self-adhesive silver mask applied to the rear, smooth 

side, of the lens. Always replace the lens the correct way 

up to ensure exact beam pattern coverage (the top of the 

Fresnel lens is marked - TOP). See fig 9.

A/M

ALARM/NC TAMPER ALARM/NO

+        -

9-15    VDC

BEAM PATTERN

SPECIFICATIONS

Microwave

Frequency

10 dBm EIRP

Operating frequency (country 

specific)

GJD369/25 - 10.525GHz 

GJD369/35 - 9.35GHz 

GJD369/87 - 10.587GHz

GJD369/41 - 10.41GHz 

GJD369/90 - 9.9GHz

Detection Area

Programmable between 10 & 30m 

Coverage

10-70 degrees detection angle, 30m x 

30m coverage max.

Adjustment

180 degree pan + 45 degree tilt

Fresnel Lens

28 zones for each Pyro pair, which can 

be masked with the curtain sliders

Customised Optics

Double silicon shielded quad element 

eliminates 50,000 Lux of White-Light

Microwave Module

Operating Frequency. Country 

dependent                              GHz  10 

dBm EIRP

Outputs

Silent solid state magnetically immune

No. 1

N/OPEN

Volt free relay signal 

contact 24VAC/DC 

@ 50mA with an 

integral 25R series 

resistor

Alarm time 5 

seconds

No.2 

N/CLOSED

Volt free relay signal 

contact 24VAC/DC 

@ 50mA  with an 

integral 25R series 

resistor

Alarm time 5 

seconds

Power Input

9 to 15 VDC

Current

15mA (12V nominal)

Pulse Count

1 -  2

Temp Compensation

Digital sensitivity adjustment

Control

Digital microprocessor - non volatile 

memory

Walk Test

Output test mode with LED indication

Operating Temp

-20ºC to +55º C

Conformally coated electronics for 

increased stability

Housing

High impact zinc alloy 

Protection Rating

IP65

Dimensions

145 x 120 x 115 mm

Weight

750grams NET, 880 grams GROSS

Mounting Height

Variable - optimum height 3 metres

Cable <200m 

Utilising all three outputs (incl. tamper) 

- 8 core 7/0.2mm

Cable <500m 

Utilising all three outputs (incl. tamper) 

- 8 core 16/0.2mm

PROGRAMMING 

The user can individually program a number of 

configurable settings as illustrated in the programming 

chart. Factory settings are shown as shaded boxes. 

Changes to the existing settings can easily be made. To 

reset the factory settings simply remove power from the 

detector, press and hold the program button (see fig 10) 

whilst temporarily applying power to the detector: either 

before installation, with a PP3 battery, or by applying 

12 volts to the unit on site. The Amber LED will flash 10 

times, the blue LED will flash 3 times then the blue LED 

will flash rapidly then release the program button.

PROGRAMMING CHART

OPTIONS

SETTING

1

2

3

1

Range (m)

10

20

30

2

Pulse Count

1

2

3

LED

OFF

ON

EXAMPLE

To change the LED setting from OFF to ON. 

1. Press the program button three times and release the 

button. 

2. Wait until the indicator goes off. 

3. The indicator will now flash once. 

4. Press the program button twice and release the button. 

5. The indicator flashes twice showing that the option has 

been stored and the detector returns to normal operation.

SIMPLIFIED EU DECLARATION OF CONFORMITY

Hereby, GJD Manufacturing Ltd declares that the radio 

equipment type GJD369 D-TECT Dual AM Detector is in 

compliance with Directive 2014/53/EU.

The full text of the EU declaration of conformity is 

available at the following internet address: gjd.co.uk