TECHNICAL SPECIFICATIONS

Specifications are subject to changes without prior notice.

All values measured in specific conditions.

Technology:
Detection mode:
Max. detection range:
Remission factor:
Angular resolution:
Min. detected object size (typ.):
(in proportion to object distance)
Testbody:
Emission characteristics:
     IR laser:
     Red visible laser:
Supply voltage:

Peak current at power-on:
Cable length:
Response time:
Output:
     Max. switching voltage:
     Max. switching current:
     Switching time:
     Output resistance:
     Voltage drop on output:
     Leakage current:
Input:
     Max. contact voltage:  
     Voltage threshold:
Response time monitoring input:
LED-signal:

Dimensions:
Material:
Colour:
Mounting angles on bracket:
Rotation angles on bracket:
Tilt angles on bracket:
Protection degree:
Temperature range:
Humidity:
Vibrations:
Pollution on front screens:
Expected lifetime:
Norm conformity:

laser scanner, time-of-flight measurement
motion and presence (EN 12453 Typ. E)
D-TECT Laser 509: 10m x 10m;D-TECT Laser 505: 5.0 m x 5.0 m
> 2 %
0,3516 °
D-TECT Laser 509: 2,1 cm @ 3 m ; 3,5 cm @ 5 m ; 7 cm @ 10 m
D-TECT Laser  505: 2,1 cm @ 3 m ; 3,5 cm @ 5 m
700 mm x 300 mm x 200 mm (testbody A according to EN 12445)

wavelength 905 nm; max. output pulse power 75 W (CLASS 1)
wavelength 650 nm; max. output CW power 3 mW (CLASS 3R)
24 VDC 3A Supply

2.625A max 80ms @ 24 VDC
10 m
typ. 20 ms; max. 80 ms (+ output activation delay)
2 electronic relays (galvanic isolated - polarity free)
35 V DC / 24 V AC
80 mA (resistive)
t

ON

=5 ms; t

OFF

=5 ms

typ 30 Ω
< 0.7 V @ 20 mA
< 10 µA
2 optocouplers (galvanic isolated - polarity free)
30 V DC (over-voltage protected)
Log. H: >8 V DC; Log. L: <3 V DC
< 5 ms
1 blue LED: power-on status
1 orange LED: error status
2 bi-coloured LEDs: detection/output status 

(green: no detection; red: detection)

125 mm (D) x 93 mm (W) x 70 mm (H) (mounting b 14 mm)
PC/ASA
black or white
-45 °, 0 °, 45 °
-5 ° to +5 ° (lockable)
-3 ° to +3 °
IP65
-30 °C to +60 °C if powered; -10 °C to +60 °C unpowered
0-95 % non-condensing
< 2 G 
max. 30 %; homogenous
20 years 
2006/95/EC: LVD; 2002/95/EC: RoHS; 2004/108/EC: EMC; 2006/42/EC: MD; 
EN 12453:2000 chapter 5.1.1.6, chapter 5.5.1 Safety device E; 
EN 12978:2009; EN ISO 13849-1:2008 Pl “d”/ CAT2;
EN 60529:2001; IEC 60825-1:2007; EN 60950-1:2005; 
EN 61000-6-2:2005; EN 61000-6-3:2006;
IEC 61496-1:2009; EN 61496-3:2008 ESPE Type 2; 
EN 62061:2005 SIL 2; DIN 18650-1:2010 Chapter 5.7.4

Certifications

Summary of Contents for D-TECT GJD505

Page 1: ...1 GJD D TECT Laser User Manual GJD509 max detection range of 10m x 10m GJD505 max detection range of 5 0m x 5 0m LASER SCANNERS FOR BUILDING AUTOMATION AND SECURITY...

Page 2: ...s responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if...

Page 3: ...laser sweep reception 3 LED signal 4 4 screw for position lock 2 5 connector 6 protection cover 7 visible laser beam 3 8 notch for tilt angle adjustment 2 9 adjustable bracket 10 cable conduit 4 1 De...

Page 4: ...ning If drilling an opening is not possible use the cable conduits on the back side of the bracket Position the bracket and fasten the 4 screws firmly in order to avoid vibrations Close the protection...

Page 5: ...G POSITIONING POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY RELAY 1 OPTIONAL FIELD RELAY 2 SAFETY FIELD NOT USED GREEN BROWN WHITE YELLOW PINK VIOLET RED BLUE WHITE RED WHITE BLUE CAUTION The di...

Page 6: ...m 5 0 m no field no field The detection field should be free of snow buildups heavy rain snowfall fog or other moving objects Stay outside of the detection field to avoid disturbances Select the corr...

Page 7: ...proximately 10 cm for every meter mounting height Example at 5 m the distance is 50 cm indoor outdoor low outdoor med outdoor high OUTPUT ACTIVATION DELAY approximate values off EX C1 C2 active on opt...

Page 8: ...h time the sensor position is changed or new objects are added to or changed in the detection zone ATTENTION This PB teach in is different from the safety field teach in When the red LED flashes very...

Page 9: ...VALUES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by rem...

Page 10: ...and BLUE cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any object s from the field Activate th...

Page 11: ...D TECT Laser 505 2 1 cm 3 m 3 5 cm 5 m 700 mm x 300 mm x 200 mm testbody A according to EN 12445 wavelength 905 nm max output pulse power 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS...

Page 12: ...12 Unit 2 Birch Business Park Whittle Lane Heywood Greater Manchester OL10 2SX www gjd co uk info gjd co uk 44 0 1706 363 998 ENGINEER NOTES...

Reviews: