9
GKD Technik Ltd
M3000004
Virtual Walls
In order to set a slew virtual wall, the foreman key switch must be in the
unlocked
position.
To set a virtual wall, press the
[MENU]
button and then
[VIRTUAL WALLS OFF]
. To set the LEFT wall
distance, press
[LEFT]
. To enter the value for the left wall, in meters from the machine centre, select
[YES]
. Alternatively, to capture the wall distance from the bucket pin position press
[NO]
, move slew left
of 0° of slew and position the bucket pin at the desired left limit and press
[YES]
. The right wall is set in
the same way, but slewed to the right of 0° of slew to capture the wall position. Select either
LEFT
,
RIGHT
or
BOTH
to activate the virtual wall/s as required.
To turn the virtual walls off, press the
[MENU]
button and then
[VIRTUAL WALLS ON]
,
select
CANCEL
.
Virtual walls will then be turned OFF.
When a slew limit is set, you will see the following on the operator main screen.
Operator Display Guide continued...
Current left
Virtual wall distance
Current right
Virtual wall distance
Distance from bucket
pin to virtual wall
Tandem Lift Duty
In order to use Tandem Lift, the foreman key switch must be in the
unlocked
position.
When using the machine as one of a pair of machines lifting a load together, the Tandem Lift mode must
be engaged. The effect of the Tandem Lift mode is to reduce the lift capacity of the machine to provide an
additional safety margin before an overturn occurs, as dictated by Network Rail Tandem Lift guidelines.
To engage Tandem Lift mode, press
[MENU]
and then
[Tandem is off]
. Tandem Lift mode will be engaged,
the machine
’
s lift capacity will be recalculated in line with Tandem Lift regulations, and on machines
certified to RIS1530 rev4 and above the blue RCI indicator lamp on the cab will blink on and off at 2
second intervals.
To turn Tandem Lift mode OFF press
[MENU]
and then
[Tandem is ON]
. Tandem Lift mode will be turned
off and the machine lift capacity will return to standard lift duties.