Printed in China
8
TROUBLESHOOTING
Condition 1: No water flows into tank
1) Make sure water supply valve is fully open.
2) Check the Debris Filter Screen for any obstruction that would restrict the water supply. To check the
debris screen, shut off the water supply. Disconnect the supply line. Remove any debris from inside the
threaded shank which might be preventing proper water flow. Reconnect and turn the water supply on,
checking for leaks.
Condition 2: Poor Flush
1) Make sure the water level in the tank is up to the water line printed on the overflow tube of the flush
valve. To increase the water level turn the adjustment screw on the fill valve clockwise to raise the float cup.
2) Make sure the push rods are the correct length. The push rods should be set to a gap of approximately
1/16” above the push buttons of the flush valve. To adjust loosen the collar on the push rod & turn the rod
counter-clockwise to extend the length. Tighten collar to secure.
Condition 3: Water continues to run
1) Check to make sure the rubber seal gasket on the flush valve is completely closed. Clear any debris from
the gasket surface & sealing area of the flush valve which may be obstructing full closure.
PART REPAIR LIST
Fill Valve – Model A1250 from R&T
Flush Valve – Model A2417 from R&T.