GLASCRAFT, INC. (“GlasCraft”)

 warrants to the original Purchaser of GlasCraft manufactured equipment 

and parts, that all GlasCraft manufactured equipment and parts will conform to their published written specifications and 

be free of defects in workmanship and material for a period of one (1) year from the original date of installation.  GlasCraft 

makes no warranty to anyone other than the original Purchaser.

If any GlasCraft manufactured part or equipment is found to be defective in workmanship or material within the one-year 

period from the date of installation, as determined solely by GlasCraft, GlasCraft, in its sole discretion, will either repair 

or replace the defective part or equipment at GlasCraft’s cost, including freight charges both ways, or credit or refund the 

purchase price for the defective equipment or part.

A warranty claim will be honored only when:

     1.   GlasCraft has been informed, in writing, of any such defect in workmanship or material within ten (10) days

           after discovery by the original Purchaser;

     2.   An official of GlasCraft has issued a return authorization number; and 

     3.  The claimed defective equipment or part has been returned to GlasCraft by the original Purchaser, freight

          prepaid (with proper return authorization number(s) attached), to:  GlasCraft, Inc., 5845 West 82nd Street, 

          Suite 102, Indianapolis, IN 46278, U.S.A.

This warranty shall not apply to any equipment or parts that have been altered or repaired by anyone other than GlasCraft 

or  to  defects  or  damage  resulting  from  improper  installation,  misuse,  negligence,  accident,  or  use  not  specified  by 

GlasCraft.  This warranty shall not apply to any equipment where any parts or components were replaced by any parts 

or components not manufactured or supplied by GlasCraft.  The decision by GlasCraft shall be conclusive and binding 

on Purchaser.   

GlasCraft does not warrant that any equipment or parts sold to Purchaser meet or comply with any local, state, federal, 

or other jurisdiction’s regulations or codes.  GlasCraft does not warrant that any equipment or part sold to Purchaser, 
when used individually or in concert with any other part, equipment, device, component

 

or process, does not infringe on 

any patent rights of any third party.  GlasCraft only warrants that it has no specific knowledge of any such infringement.

GlasCraft makes no warranty as to any parts or equipment manufactured by others.  Purchaser shall look solely and 

only to the manufacturer of such parts or equipment with respect to any warranty claims.  GlasCraft hereby assigns to 

Purchaser the original manufacturer’s warranties to all such equipment and parts, to the full extent permitted.

THE AFORESAID WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IM-

PLIED.  SPECIFICALLY THERE ARE NO WARRANTIES OF MERCHANTABILITY OR FITNESS 

FOR A PARTICULAR PURPOSE, WHICH WARRANTIES ARE SPECIFICALLY DISCLAIMED.

GlasCraft shall not be liable for any loss or expense resulting from damage or accidents caused by improper use or ap-

plication of materials manufactured or sold by GlasCraft or its distributors or agents.  

UNDER NO CIRCUMSTANCES SHALL GLASCRAFT’S LIABILITY EXCEED THE AMOUNT PUR-

CHASER PAID FOR THE CLAIMED DEFECTIVE EQUIPMENT OR PART. UNDER NO CIRCUM-

STANCES SHALL GLASCRAFT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAM-

AGES OR FOR LOST PROFITS.

No action arising from or relating to any goods manufactured by or purchased from GlasCraft may be brought more than 

one (1) year after the cause of action accrues.

Limited Warranty Policy

Summary of Contents for Probler P2

Page 1: ...ET INDIANAPOLIS INDIANA 46278 U S A Phone 317 875 5592 Fax 317 875 5456 Email gcisales glascraft com Web www glascraft com Probler P2 Delayed Air Purge Dispense Counter Guardian Series Options USER MA...

Page 2: ...Safe Handling and Use of Foam Equipment 10 Installation Optional Guardian Mount Installation 14 Delayed Air Purge Gun Installation 15 Delayed Air Purge Installation 17 Dispense Counter Gun Installatio...

Page 3: ...t assembly instructions provided This manual provides information for the assem bly operation maintenance and service of this GlasCraft product as used in a typical configu ration While it lists stand...

Page 4: ...00 DELAYED AIR PURGE ASSEMBLY GC 1409 USER MANUAL Model Delayed Air Purge Standard Equipment 23997 00 DISPENSE COUNTER GC 1409 USER MANUAL Model Dispense Counter Optional Equipment 23949 00 GUARDIAN...

Page 5: ...ignal air to the DSV allowing the gun to be operated normally with out the delay action of air purge DISPENSE COUNTER FEATURES The control box receives a signal when the gun trigger is activated to ac...

Page 6: ...23996 00 Delayed Air Purge Assembly REVISION A...

Page 7: ...23996 00 Delayed Air Purge Assembly REVISON A...

Page 8: ...00 SPOOL VALVE 1 22212 01 BULKHEAD FITTING 1 22212 02 BULKHEAD FITTING 2 22218 00 PUSH ON HOSE FITTING 9 22230 00 REGULATOR FILTER 1 22237 00 HEX STANDOFF 2 22240 00 VALVE MOUNTING PLATE 1 22242 00 PR...

Page 9: ...23997 00 Dispense Counter Assembly REVISION A...

Page 10: ...REVISION A 23997 00 Dispense Counter Assembly...

Page 11: ...ALVE 1 22205 00 L FITTING 1 22212 01 BULKHEAD FITTING 2 22212 02 BULKHEAD FITTING 2 22218 00 PUSH ON HOSE FITTING 13 22219 00 PREDETERMINING COUNTER 1 22230 00 REGULATOR FILTER 1 22237 00 HEX STANDOFF...

Page 12: ...der the Occupational Safety Health Act OSHA particularly the following sections 1910 94 Pertaining to ventilation 1910 106 Pertaining to flammable liquids 1910 107 Pertaining to spray finishing opera...

Page 13: ...lements In contact with these metals HHC solvents could generate a corrosive reaction of a catalytic nature 3 Equipment capable of withstanding pres sure When HHC solvents contact aluminum or galva ni...

Page 14: ...of storage or where solvents and other flammable materials are used Adequate ventilation as covered in OSHA Section 1910 94 and NFPA No 91 is important wherever sol vents are stored or used to minimiz...

Page 15: ...or example at a construction site inside building or other enclosed space the forced ventilation normally provided is likely to be inadequate These applications therefore usually REQUIRE the use of fo...

Page 16: ...14 Optional Guardian Mount Installation 1 Install the mounting bracket 23949 00 by securing the band clamps to the frame as shown...

Page 17: ...ove the side blocks air cap 23961 00 and nose of gun 2 Remove o ring 7554 06 from handle and install plug 23998 00 3 Re install nose and air cap 4 Remove the two 10 32 plugs 9936 08F from gun handle a...

Page 18: ...he 9704 03 air trigger tubing connects to this fitting 6 Install 20796 02 on the back right port the 20732 04 signal air tubing connects to this fitting 7 Reinstall side blocks after initial system st...

Page 19: ...lay box and timer box to be mounted to Guardian series systems HOSES 1 Main air Connect air hose 19507 03 from an accessory port on the Guardian air manifold or line source to the air inlet regulator...

Page 20: ...back side of inlet regulator run tubing with the main hose assembly up to gun see gun installation 4 Air Signal Connect tubing 20732 04 to the 5 32 port on bottom of box run tubing with the main hose...

Page 21: ...PG 19 and 10 32 plug 9936 08F from back of gun 2 Install 20796 02 in 10 32 port the 20732 04 signal air tubing connects to this fitting 3 Install 19938 00 spring 19937 01 cylinder adapter 19936 00 cyl...

Page 22: ...unted to the operators discretion bracket kit 23949 00 allows both the Delay box and timer box to be mounted to Guardian series systems HOSES 1 Main air Connect 19507 03 from accessory port of Guardia...

Page 23: ...ntrol the box to the drive cylinder switches See signal switch paragraph 2 locate upper signal tubing clear and cut line 1 from signal valve 3 Locate lower signal tubing blue and cut line 1 from signa...

Page 24: ...s is the 5 32 bulkhead fitting to the inside of the bottom plate 2 Cut 5 32 line and install 22224 00 tee install 20732 03 tubing 3 Remove 22218 00 barb fitting from bottom of control box and install...

Page 25: ...Connect 9704 53 to fitting in bottom of box center route this hose with main hose assembly up to gun See gun installation 2 Air Signal Connect 20732 04 to 5 32 port on bottom left of box run hose w m...

Page 26: ...of trigger on to fully engage the delay spool deactivate the air purge START UP PNEUMATIC COUNTER 1 Prime system per manual instructions 2 Set air regulator to 100 psi this is recommended operation p...

Page 27: ...Notes 25...

Page 28: ...Notes 26...

Page 29: ...arts or components were replaced by any parts or components not manufactured or supplied by GlasCraft The decision by GlasCraft shall be conclusive and binding on Purchaser GlasCraft does not warrant...

Page 30: ...t You can e mail all correspondence to service glascraft com For Air Powered Systems Model _____________________________ Air compressor size __________________ Serial number _______________________ CF...

Page 31: ...in plant or a field contractor GlasCraft has a system package to meet your requirements GUARDIAN AIR POWERED A5 A6 SERIES EQUIPMENT 6000 OR 12000 WATTS OF HEAT 1600 2200 OR 3000 PRESSURE SET UPS AVAI...

Page 32: ...Quality and Performance GENUINE GLASCRAFT www glascraft com GC 1409 REVISION A 2 5845 WEST 82nd STREET INDIANAPOLIS INDIANA 46278 U S A Phone 317 875 5592 Fax 317 875 5456 E Mail sales glascraft com...

Reviews: