1. InsPectIOn uPOn arrIVal 

 

  •  Immediately upon receipt of the unit, make a visual  

 

  inspection of the carton to determine if there is evidence    

  of damage.  Following un-crating, make an inspection for  

  signs of damage.

  •  If damage is found, notify the carrier immediately.

 

  •  The Transportation Company is liable for damage sustained  

  during shipment but claims must be made with in 15 days.

     

 

 

 

2. lOcatIOn Of reMOte cOOler

 

  •  Unit can be placed up to 150 ft. (45.7m.) from the dispens- 

  ing station.  The low profile design allows the unit to be    

  located under counter.

  •  If unit is installed on the floor:

    a)   the cabinet must be sealed to the floor with an NSF    

    listed silicon RTV applied around the entire periph-   

    ery of the cabinet (see fig.1) 

    b)  optional 6” legs must be installed to the cabinet bottom.

  •  If unit is installed on a countertop or shelf:

    a)  the cabinet must be sealed to the countertop or shelf    

    with an NSF listed silicon RTV applied around the    

    entire periphery of the cabinet.  (see fig.1)

    b)  optional 4” legs must be installed to the cabinet bottom.

  •  Any location must have the ability to support the operat-   

  ing weight of the unit.  (261 lbs./118 kg.)

  •  Avoid obstructions to the air intake and exhaust sections    

  of the unit.

  •  Minimum clearance between the top, front, and back of unit  

  and any obstruction is 12 in. (30.5cm.)

  •  Proper unrestricted airflow is essential.

  •  After the unit is in place, check to be sure it is level.

3. reMOVIng the frOnt cOVer

 

  •  Remove the three-(3) screws in front of the unit, and two-   

  (2) screws on top rear. (see fig.2)

  •  Lift cover up to disengage from rear of the unit, then  

 

  pull forward.

  •  Do not remove the screws along the sides or back.

i

nsPeCtion

 

and

 L

oCation

fig. 1

  Sealing Cabinet with RTV

fig. 2

  Removal of Front Cover

CABINET BOTTOM

RTV TO FORM A FILL

ET WHEN

CABINET PLACED UP

RIGHT

RTV

Summary of Contents for LC84

Page 1: ...ichigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com Operation Manual and Parts Directory LC84 Conquest Post Mix Remote Soda Line Chiller 2006...

Page 2: ......

Page 3: ...Cleaning Hints 4 Water Bath Cleaning and Maintenance 4 Sanitizing Water Circuits 4 Sanitizing Syrup Circuits 4 Preventative Maintenance Schedule 5 Trouble shooting procedures Poor Carbonation 6 Bad T...

Page 4: ...ional 6 legs must be installed to the cabinet bottom If unit is installed on a countertop or shelf a the cabinet must be sealed to the countertop or shelf with an NSF listed silicon RTV applied around...

Page 5: ...standard equipment Before connecting water supply drain approximately two gallons of water from supply to flush out foreign matter It is recommended that a water filtering systems be installed to red...

Page 6: ...reely without spurting Adjust the syrup regulator to 50 P S I Adjust diet syrup regulator if used to 12 P S I Check all connections for leaks Insulate and tape all exposed refrigerated conduit lines A...

Page 7: ...nd pump deck Clean coils and inside of tank with soap or detergent and rinse with water Replace motor and pump deck Replace refrigeration deck Plug cord from refrigeration deck back into control box R...

Page 8: ...ice Weekly Dispensing Follow Standard Brixing Tower Brix Instructions Check Weekly Remote Cooler Wash With Mild Detergent And Wipe Dry Weekly System Review Pressure Gauges Pressures For Proper Setting...

Page 9: ...itch With switch in ON fully opened Incoming water supply to unit should be 3 8 I D minimums Be sure pump and pump motor are properly aligned and the clamp is tight Broken vanes in pump requiring pump...

Page 10: ...inks per minute Pull Down 6 9 hours operational Maximum Distance to Dispensers 150 ft 46 m Carbonator Integral cold carbonator Carbonator Pump 100 gph 378 lph Carbonator Motor 1 3 HP 25 kW Circulating...

Page 11: ...for ventilation and servicing Top front sides are one piece and are removable for servicing the compressor 1 625 Air Intake On Off Switch Compressor Area Under cover Exhaust Exhaust Exhaust Exhaust E...

Page 12: ...Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com Typical Installation Diagrams Typical Installation Using bag in box syrup system Typical Installat...

Page 13: ...hs from date of factory shipment whichever occurs sooner Glastender Inc will replace any part or assembly found defective under normal use and service Field replacement parts include a warranty of 90...

Page 14: ...5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com 11 LC84 Compressor and Related Parts 1 2 3 5 4 8 6 7 9 10 11 13 14 15 16 17 1...

Page 15: ...tion pump white set of 2 pieces 9 00 10 09000261 GT 031404 104 exterior power cord 20 00 11 09000412 GT 037112 Carbonator tank 115V 415 00 12 09000479 GT 034114 Relay compressor 20 00 09000480 GT 0312...

Page 16: ......

Reviews: