background image

Glastender, Inc.  •  5400 North Michigan Road  •  Saginaw, MI  •  48604-9780  

800.748.0423  •  989.752.4275  •  Fax 800.838.0888 / 989.752.4444  •  www.glastender.com

5

PreVentIVe MaIntenance scheDule

Daily   

 

 

Syrup Tank   

 

When Cleaning Tanks

 

 

 

 

Connectors   

 

Rinse Both Quick Connects

 

 

 

 

 

 

 

 

In Clean Warm Water.   

Daily   

 

 

Dispensing   

 

Wash Nozzle And Diffuser

 

 

 

 

Valves  

 

 

In Warm Soapy Water And

 

 

 

 

 

 

 

 

Rinse In Warm Water

Daily   

 

 

Dispensing    

 

Wash With Mild Detergent

 

 

 

 

Towers  

 

And Warm Water, Then

 

 

 

 

 

 

 

 

Wipe Dry. Flush Drain

 

 

 

 

 

 

 

 

With Warm Water

Twice Weekly  

Dispensing   

 

Follow Standard Brixing

 

 

 

 

Tower Brix   

 

Instructions

 

 

 

 

Check   

 

 

Weekly 

 

 

Remote Cooler 

 

Wash With Mild Detergent

 

 

 

 

 

 

 

 

And Wipe Dry

 

Weekly 

 

 

System  

 

Review Pressure Gauges

 

 

 

 

Pressures 

 

 

For Proper Settings

Monthly 

 

 

Remote Cooler 

 

Clean Condenser With A

 

 

 

 

Air Cooled   

 

Soft Bristled Brush Or

 

 

 

 

Condenser 

 

 

Vacuum Cleaner

Every 6 Months 

 

Syrup Lines   

 

Follow “SANITIZING  

 

 

 

 

 

 

 

 

 

SYRUP CIRCUITS”   

 

 

 

 

 

 

 

 

Instructions

Every 6 Months 

 

Water Lines   

 

Follow “SANITIZING  

 

 

 

 

 

 

 

 

 

WATER CIRCUITS”

Every 6 Months 

 

Water Bath   

 

Follow “WATER BATH

 

 

 

 

 

 

 

 

DRAINING AND CLEANING”

 

 

 

 

 

 

 

 

Instructions

Every 6 Months 

 

Lubrication   

 

Lubricate Circulating And

 

 

 

 

 

 

 

 

Carbonator Pump Coupling    

 

 

 

 

 

 

 

 

With 3-5 Drops Of SAE 20    

 

 

 

 

 

 

 

 

Non-Detergent Oil

C

Leaning

 

and

 M

aintenanCe

Summary of Contents for LC84

Page 1: ...ichigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com Operation Manual and Parts Directory LC84 Conquest Post Mix Remote Soda Line Chiller 2006...

Page 2: ......

Page 3: ...Cleaning Hints 4 Water Bath Cleaning and Maintenance 4 Sanitizing Water Circuits 4 Sanitizing Syrup Circuits 4 Preventative Maintenance Schedule 5 Trouble shooting procedures Poor Carbonation 6 Bad T...

Page 4: ...ional 6 legs must be installed to the cabinet bottom If unit is installed on a countertop or shelf a the cabinet must be sealed to the countertop or shelf with an NSF listed silicon RTV applied around...

Page 5: ...standard equipment Before connecting water supply drain approximately two gallons of water from supply to flush out foreign matter It is recommended that a water filtering systems be installed to red...

Page 6: ...reely without spurting Adjust the syrup regulator to 50 P S I Adjust diet syrup regulator if used to 12 P S I Check all connections for leaks Insulate and tape all exposed refrigerated conduit lines A...

Page 7: ...nd pump deck Clean coils and inside of tank with soap or detergent and rinse with water Replace motor and pump deck Replace refrigeration deck Plug cord from refrigeration deck back into control box R...

Page 8: ...ice Weekly Dispensing Follow Standard Brixing Tower Brix Instructions Check Weekly Remote Cooler Wash With Mild Detergent And Wipe Dry Weekly System Review Pressure Gauges Pressures For Proper Setting...

Page 9: ...itch With switch in ON fully opened Incoming water supply to unit should be 3 8 I D minimums Be sure pump and pump motor are properly aligned and the clamp is tight Broken vanes in pump requiring pump...

Page 10: ...inks per minute Pull Down 6 9 hours operational Maximum Distance to Dispensers 150 ft 46 m Carbonator Integral cold carbonator Carbonator Pump 100 gph 378 lph Carbonator Motor 1 3 HP 25 kW Circulating...

Page 11: ...for ventilation and servicing Top front sides are one piece and are removable for servicing the compressor 1 625 Air Intake On Off Switch Compressor Area Under cover Exhaust Exhaust Exhaust Exhaust E...

Page 12: ...Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com Typical Installation Diagrams Typical Installation Using bag in box syrup system Typical Installat...

Page 13: ...hs from date of factory shipment whichever occurs sooner Glastender Inc will replace any part or assembly found defective under normal use and service Field replacement parts include a warranty of 90...

Page 14: ...5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com 11 LC84 Compressor and Related Parts 1 2 3 5 4 8 6 7 9 10 11 13 14 15 16 17 1...

Page 15: ...tion pump white set of 2 pieces 9 00 10 09000261 GT 031404 104 exterior power cord 20 00 11 09000412 GT 037112 Carbonator tank 115V 415 00 12 09000479 GT 034114 Relay compressor 20 00 09000480 GT 0312...

Page 16: ......

Reviews: