Page 30
Model
Volume to be added to the system (litres)
Corrosion inhibitor agent
Sentinel X100
Fernox MB1
BMAS 150 OVR
1½
1½
BMAS 180 OVR
2
2
BMAS220 OVR
2¼
2¼
INSTALLATION
COMMISSIONING
Open the incoming stop valve and fill the domestic mains cold and hot water systems.
Fill the whole of the primary heating system with potable water through the feed
and expansion cistern.
Check the water level in the feed and expansion cistern and adjust the ballvalve if
necessary.
Check the whole of the primary heating and domestic hot and cold distribution
system, including the boiler and BoilerMate OVR, for leaks.
It is essential that all systems function properly for optimum performance.
To achieve this, the primary system should be commissioned in accordance with good
practice and generally in accordance with the requirements of BS 6798, BS 5449 and
BS 7593.
Full details of the requirements are given in PAS 33:1999 under the Commissioning
Section.
When using either cleansing or corrosion inhibitor chemical, the manufacturers
instructions must be followed.
Cleansing the Primary System
When determining the quantity of cleanser
required, be sure to allow for the increased
volume of water in the primary circuit due
to the thermal store - see the Technical data
section for volumes.
In most cases the quantities shown opposite
will be adequate for up to a typical 3/4
bedroom property.
Primary Water System Treatment
Although the BoilerMate has no special water
treatment requirements, the radiators and
other parts of the circuit will benefit from the
application of a scale and corrosion inhibitor
such as Sentinel X100 or a Protector such as
Fernox MB1.
When determining the quantity of inhibitor
required, be sure to allow for the increased
volume of water in the primary circuit due
to the thermal store - see the Technical Data
section for volumes.
In most cases the quantities shown opposite
will be suitable for up to a typical 3/4 bed
property.
Powerflushing/cleaning Of The Heating
System
If it is proposed to ‘powerflush’ the heating
system we would recommend that the
BoilerMate appliance is isolated from the
heating system being cleaned. Failure to do
this could seriously damage the appliance.
When carrying out the work always comply
fully with the manufacturers instructions for
the powerflushing equipment being used.
Model
Volume to be added to the system (litres)
Cleansing agent
Sentinel X300
Fernox Superfloc
BMAS 150 OVR
1½
1½
BMAS 180 OVR
2
2
BMAS220 OVR
2¼
2¼