Model
BMAS 150 OVR
BMAS 180 OVR
BMAS220 OVR
Energy efficiency class
C
C
C
Heat loss (watts)
66
72
88
Heat loss (kWh/24hr)
1.58
1.73
2.11
Weight (empty)
51.5
54.5
61.5
Weight (full)
192
213
265
DHW Pump
Grundfos UPR 15/50
Grundfos UPR 15/50
Grundfos UPR 15/50
Heating Pump
Grundfos ErP Ready 15/50
Grundfos ErP Ready 15/50
Grundfos ErP Ready 15/50
Boiler Pump
Grundfos ErP Ready 15/50
Grundfos ErP Ready 15/50
Grundfos ErP Ready 15/50
Primary/heating pipe connections
22mm
22mm
28mm
MCW & DHW pipe connections
22mm
22mm
22mm
Cold feed/expansion connection
22mm
22mm
22mm
Safety open vent connection
22mm
22mm
22mm
Maximum summer towel rail load
0.75kW
1.00kW
1.25 kW
Drain connection
R ½”
R ½”
R ½”
Maximum Head
6 meters
6 meters
6 meters
Hot water flow rate (l/m) up to
35
35
35
Max heating system size
17 kW
20 kW
25 kW
Typical Dwelling Types
Bedrooms
2-3
2-4
3-5
Bathrooms
1
2
1
2
En-suite shower
2
1
4
2
TECHNIC
AL
D
AT
A
DESIGN
Notes:-
1. In many cases, large properties will benefit from having 2 smaller appliances located
adjacent to the areas of peak hot water use. This will allow 2 heating zones to be
provided and remove the need to provide trace heating on the hot water system.
2. A plastic feed and expansion cistern will be supplied separately including ballvalve,
float and overflow fitting.
3. The flow rates are based on a 35°C temperature rise and assume normal pressure
and adequate flow to the appliance. The actual flow rate from the appliance is
automatically regulated to a maximum of 28 litres/min.
4. Unit is supplied on a 100mm high installation base.
5. The domestic hot water outlet temperature is automatically regulated to
approximately 52°C at the bath flow rate of 18 litres/min recommended by BS
6700. The temperature is not user adjustable.