Page 30
2.2 INSTALLATION
2.0 INSTALLATION
'A' Class Boilermate SP
No Clock ver .FC7
Bl
Bl
Bl
Bl
Bl
R
R
R
G/Y
G/Y
Br
Br
Br
Br
Br
Br
Y
Br
Br
Br
Br
Br
Y
B
Y
B
O
O
B
B
G
Wh
Wh
Wh
Wh
Remove Link
To
F
it
Room Thermostat
Gr
Br
Bl
Gr
Or
N/C
Br
Bl
Br
B
Or
Wh
Br
Br
Bl
Bl
Bl
Bl
R
Bl
Bl
R
R
R
G/Y
Br
BR
BR
R
R
R
Bl
B
Or
Wh
Or
Wh
B
BL
Br
Bl
Bl
Br
Br
B
B
Br
G/Y
G/Y
R
Wh
R
R
RR
O
O
B
B
Y
Y
S4
S5
S6
ID_RESISTOR
S3
S1 & S2
FRONT
P
A
NEL
'MODE'
Switch
Neon Illuminated
ON / OFF Switch
Red LED
Push Button
J33
J32
J34
J28
J29
J5
J3
J30
J31
J9
L
L
N
N
E
E
M
M
SL_B
SL_R
SL_W
SL_H
VA
L_SL
E
N
E
VA
L_L1
E
VA
L_L2
E
VAL
_N
L3
L2
L1
N
N
N
MCB 2
MCB 1
MCB 3
16A
6A
16A
HTG Switched Live
Room stat S/W Live (L)
HW Switched Live
Boiler S/W Live (L)
Live
(L) 230 V ac
Neutral
Main Supply
230V 50Hz 32A
(6.0 mm² T
& E cable)
* All wire sizes 0.5mm² unless otherwise stated
2.5mm² HIGH TEMP
2.5mm² HIGH TEMP
2.5mm² HIGH TEMP
2.5mm² HIGH TEMP
2.5mm² HIGH TEMP
2.5mm² HIGH TEMP
2.5mm² HIGH TEMP
2.5mm² HIGH TEMP
N
L
2
3
4
1
ON
SPD1/2A
OPTIONAL EXTRA
IF FITTED
(P
AR
T
No XB142)
SCALE INHIBIT
O
R
2 x 3kW Heating Elements
S 3
S 4
S 5
S 6
Store overheat sensors
Cold W
a
ter IN
Domestic Hot W
a
ter OUT
Bottom Immersion Heater
2K2 Resistor (Black) A_02
T
op Immersion Heater
S1 & S2
ID_RESIST
OR
SENSOR LEGEND
BLUE
Bl
BROWN
Br
GREEN
GREY
GREEN / YELLOW
G
Gr
G/Y
WIRE COLOUR LEGEND
BLACK
ORANGE
YELLOW
WHITE
RED
B
Or
Y
Wh
R
Black Covering
Flat Ribbon Cable
(1) Connection only used
if Modulating Pump is fitted
(1)
(1)
24
23
13
14
RELA
Y
R1
A1
A2
200 - 240V
ac 50Hz
('SWITCH' ON / OFF)
(Boiler ON / OFF)
(Heating S-L)
(Hot W
a
ter S-L)
(Room Stat S-L)
DHW
Pump
Boiler
Pump
G/Y
Or
Wh
BL
R
J33
J32
J34
J28
J29
J5
J3
J30
J31
J9
(1)
(1)
B
A
AB
Br
Br
B
B
R
Or
R
Or
4.0mm High T
e
mp
4.0mm High T
e
mp
2
2
Remove Links T
o
Fit
3rd Party Clock
3
12
8
7
6
5
4
A
B
C
D
E
DRG. NAME
DRG. SIZE
JOB NAME
TITLE
BOILERMA
TE 'A' Class SP
with No Clock
Electrical Schematic for BOILERMA
TE 'A' class SP
appliance with no clock fitted.
ISSUE No : 1
APPROVED
DA
TE : SEPTEMBER 2005
A3
GLEDHILL
W
A
TER ST
ORAGE L
T
D.
DO NOT
SCALE FROM THIS DRA
WING. COPYRIGHT
OF THIS DRA
WING
IS RESER
VED. IT
IS NOT
T
O
BE REPRODUCED COPIED OR DISCLOSED
T
O
A
THIRD P
A
R
T
Y
EITHER WHOLL
Y
OR IN P
A
R
T
WITHOUT
OUR
WRITTEN CONSENT
.
© GLEDHILL
W
A
TER ST
ORAGE L
T
D.
SYCAMORE TRADING EST
A
T
E
SQUIRES GA
TE LANE
BLACKPOOL
LANCASHIRE
FY4 3RL
DRN.
SIGN.
SIGN.
DA
TE
DA
TE
APP'D.
CH'KD.
DA
TE
21-09-05
21-09-05
21-09-05
G Bott
S. Gataora
S. McGachie
Summary of Contents for BMA 120 SP
Page 44: ...Page 44 ...