1.0 DESIGN
1.2 TECHNICAL DATA
Note: The Appliance dimensions above do not allow for
the100mm high installation base
The following table of minimum cupboard dimensions only
allow the minimum space required for the appliance (including
the F & E cistern) and any extra space required for shelving etc
in the case of airing cupboards etc must be added.
Note: The above dimensions are based on the Appliance and
the F & E cistern being in the same cupboard.
If the standard manual fi ll model is chosen the height can be
reduced by 100mm.
If the appliance is to be connected to a multi-zone heating
then an additional 150mm must be added to the above
heights to accomodate the space required for the zone
equipment eg valves.
APPLIANCE DIMENSIONS
MODEL
Height
Width
Depth
A
B
C
BMA 120 SP
960mm
530mm
595mm
BMA 140 SP
1000mm
530mm
595mm
BMA 180 SP
1040mm
530mm
595mm
BMA 200 SP
1145mm
530mm
595mm
BMA 220 SP
1300mm
530mm
595mm
MINIMUM CUPBOARD DIMENSIONS
MODEL
Height
Width
Depth
D
E
F
BMA 120 SP
1710mm
630mm
600mm
BMA 140 SP
1750mm
630mm
600mm
BMA 180 SP
1790mm
630mm
600mm
BMA 200 SP
1895mm
630mm
600mm
BMA 220 SP
2050mm
630mm
600mm
"
%
MMMINCLEAROPENINGIF
LOCATEDDIRECTLYINFRONTOFTHE
APPLIANCE
-AINTENANCE
ACCESS
-INMAINTENANCE
ACCESSTOCOMPLYWITH
THE7ATER2EGULATIONS
#50"/!2$
&
#
MM
MM
MM
MM
MM
MM
$
!
&%#ISTERN
&%#ISTERN
PLAN
"OILER-ATE!#LASS