Page 29
‘A’ Class Boilermate HP-DEM issue 4.ai
Bl
Bl
Bl
Bl
R
R
R
R
Br
Br
Y
Br
Br
Br
Y
B
Y
B
G
Wh
Wh
Wh
B
BL
Br
Bl
Bl
Bl
Br
Br
Br
B
B
B
Br
G/Y
G/Y
G/Y
R
O
O
B
B
Y
Y
S4
S3
S1 & S2
J33
J32
J28
J29
J3
L
L
L
N
N
N
E
E
E
M
M
M
* All wire sizes 0.5mm² unless otherwise stated
Y
(1) Connection only used
if Modulating Pump is fitted
(1)
(CH Zone 1 Electric Boost)
(How Water Electric Boost)
(Heating SL-H)
(Hot Water SL-W)
(Comfort Cooling call SL-C)
(Room Stat SL-R)
CH Z2
Pump
System
Pump
Heat Pump
Pump
Bl
Br
Br
Green Neon Illuminated
ON / OFF Switch
1b
1a
1
O
I
1a
1b
1
Rocker Switch
terminal
conections
HW Valve
B
A
Normally
Closed
3
Speed
3
Speed
Br
Br
O
O
Br
Wh
S5
S6
Br
Wh
R
Blue
Bl
Brown
Br
Green
Grey
Green / Yellow
G
Gr
G/Y
WIRE COLOUR LEGEND
Black
Orange
Yellow
White
Red
B
Or
Y
Wh
R
S 3
S 4
S 5
S 6
Hot Water overheat sensors
Hot Water Control sensor
Zone 1 CH Flow Sensor
Heat Pump Return sensor
Outside Temperature Sensor
Heat Pump Flow sensor
S1/S2
SENSOR LEGEND
S 7
3
Speed
Multicore Signal Cabel
to Mitsubishi Air Source
Heat Pump Terminals.
P2
P1
P3
Com
N/O
R
N/C
Bl
(Hot Water Valve V1)
(CH Zone 1 Valve V2)
G/Y
Or
Wh
Bl
J34
J5
J30
J31
J9
(1)
Br
Br
Br
MCB 2
MCB 1
MCB 3
16A
6A
16A
Mains Supply
230VAC 50Hz 32Amps
6.0 / 10.0mm² Twin & Earth Cable PVC
(10.0mm² is only required when there is a high
ambiant temperature and/or long cable run)
N
L
N
E
CH1
HOT WATER
CH2
CH ZONE 1
TWO CHANNEL DIGITAL CLOCK
1
2 3
6
4 5
7
M
~
8
147MP_34
147DI_2
147-HP
S7
Outside
Temperature
Sensor
Wh
Z1
RS
L
Z1
RS
SL
Z1
RS
N
Z2
RS
L
Z2
RS
SL
Z2
RS
N
Z2
RS
E
V1
L
V2
L
V
N
V
S2
O
W
C
O
W
C
HP
A1
HP
A2
HP
A3
HP
A4
HP
A5
HP
B1
HP
B2
HP
B3
F
U
S
E
OWC
Wh
A1
B1
A5
A4
A3
A2
B2
B3
100mA
@12 VDC
20mm
Fuse
A2 A1
HW-B
CH-Z1-B
3kW
Room thermostat
call for Zone 1 Only
Programmable
Room thermostat
call for Zone 2 Only
Z1
RS
E
V
S1
2.5 mm SID
Silicone
2
3kW
3 WAY BUS BAR
2.5 mm SID
Silicone
2
Remove link
to wire room
thermostat
Br
B
F1
14
11
12
R1 CC
3
1
2
8
7
6
5
4
A
B
C
D
E
DRG. NAME
DRG. SIZE
JOB NAME
TITLE
'A' Class BoilerMate
Heatpump HP-DEM
Electrical Schematic for :
‘A’ Class BoilerMate Heatpump HP-DEM
ISSUE No : 4
APPROVED
DATE : NOV 2007
A3
GLEDHILL WATER STORAGE LTD.
DO NOT SCALE FROM THIS DRAWING. COPYRIGHT OF THIS DRAWING
IS RESERVED. IT IS NOT TO BE REPRODUCED COPIED OR DISCLOSED
TO A THIRD PARTY EITHER WHOLLY OR IN PART WITHOUT OUR
WRITTEN CONSENT.
© GLEDHILL WATER STORAGE LTD.
SYCAMORE TRADING ESTATE
SQUIRES GATE LANE
BLACKPOOL
LANCASHIRE
FY4 3RL
DRN.
SIGN.
DATE
DATE
APP'D.
CH'KD.
DATE
06-11-07
06-11-07
06-11-07
S. McGachie
S. Gataora
S. Gataroa
CH Valve
B
A
Normally
Closed Z1
SIGN.
V2
V1
V
E
2.5 mm SID Silicone
2
C2
A1
A2
2
4
1
3
J5
J4
J3
J7
J11
J8
J10
J2
J1
T1
K1
K2
K3
K3
S1
ON
C2
ISO1
ISO2
C1
J6
C1
A1
A2
2
4
1
3
L1 L2
2.5 mm SID Silicone
2
L3
2.5 mm SID Silicone
2
Br
Bl
N
L
2 3 4
1
ON
SPD1/2A
OPTIONAL EXTRA
IF FITTED, THIS
AREIAL IS WRAPPED
AROUND THE COLD
WATER MAINS FEED
PART No.
XB142
WIRING DIA
GR
AM
INSTALLATION