SELECTION
BOILERMATE SP PP
Technical Specification BoilerMate SP Pre-Plumbed
Product Stock Code
BMSTSP150PP
BMSTSP180PP
BMSTSP210PP
Energy efficiency class
C
C
C
Heat loss
watts
47
55
62
kWh/24hr
1.48
1.78
2.08
Height
mm
1118
1306
1494
Diameter
mm
550
550
550
Min cupboard height
1
mm
1668
1856
2044
Min cupboard width
mm
670
670
670
Min cupboard depth
mm
670
670
670
Weight (empty)
kg
42
46
55
Weight (full)
kg
193
227
266
Thermal store volume
litres
151
181
211
DHW dedicated volume
litres
151
181
211
DHW space heating volume
litres
Average reheat power
2
kW
21
19
19
Average reheat time
3
mins
18
26
29
Maximum DHW pressure
bar
5
5
5
DHW performance
Test flow rate
litres/min
12.6
12.6
12.6
Test volume above 40°C
litres
138
154
196
Average DHW temperature
°C
54
53
55
Average temperature rise
°C
41
41
43
Thermal store test temperature
°C
75
75
75
Notes:-
1. The height stated is to the top of the unit plus 550mm, which should allow for a 25mm thick shelf/board and room for servicing. This
will need to be increased by 125mm if the automatic fill method is chosen.
2. SP model heated from a heat source at 82.5°C at 16 l/m.
3. Full thermal store volume reheated from 35°C to 75°C.
4. Please refer to page 5 for the minimum cupbard space requirement. This can be reduced by approximately 70mm if the insulation
is removed from the plate heat exchangers.
Summary of Contents for BOILERMATE OV PP
Page 47: ...Page 47 APPENDIX APPENDIX B ...