Page 5
DESIGN
INTRODUCTION
1
2
3 4
6
7
D
ra
in
Wiring Centre
Immersion
Control Stat
2a
Cyli
nde
r C
old
Fe
ed
(to
F &
E)
8
5
Number
Description
Size (mm)
1
Return To Boiler
22
2
CH Zone 1
22
2a
Optional CH Zone 2
22
3
Flow From Boiler
22
4
CH Return
22
5
Drain
½" Fem
6
Hot Water Out
22
7
Mains Cold Supply
22
8
Cylinder Cold Feed
22
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
0
280
474
540
592
609
617
670
0
83
15
3
20
2
22
5
28
2
33
5
50
8
53
7
67
0
0
280
591
617
670
670
Minimum Cupboard Width =
12°
45°
1
3
6
7
Dra
in
Wiring Centre
Immersion
Control Stat
Cyli
nde
r C
old
Fe
ed (
to F
& E
)
5
8
Number
Description
Size (mm)
1
Return To Boiler
22
2
N/a
22
2a
N/a
22
3
Flow From Boiler
22
4
N/a
22
5
Drain Tapping
½" Fem
6
Hot Water Out
22
7
Mains Cold Supply
22
8
Cylinder Cold Feed
22
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
0
280
637
670
0
17
4
27
1
33
5
50
8
53
7
67
0
0
280
591
617
670
670
Minimum Cupboard Width =
58°
45°
3
2
1
4
6
7
Dra
in
Wiring Centre
Immersion
Control Stat
2a
5
8
Cyli
nde
r C
old
Fe
ed
(to
F &
E)
Number
Description
Size (mm)
1
Return To Boiler
28
2
CH Zone 1
22
2a
Optional CH Zone 2
22
3
Flow From Boiler
28
4
CH Return
22
5
Drain Tapping
½" Fem
6
Hot Water Out
22
7
Mains Cold Supply
22
8
Cylinder Cold Feed
22
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
0
280
593
623
644
670
0
94
17
6
23
9
33
5
42
4
50
8
53
7
67
0
0
280
591
617
623
670
670
Minimum Cupboard Width =
58°
45°
Model Selection Guide BoilerMate
Dwelling Type
Bedroom
1-2
2-3
2-3
2-4
Bathroom
1 or
1
1
2
En-suite shower rooms
1
1
2
1
Model size required
150
150
180
210
Notes:-
1. Plastic top up cistern will be supplied separately.
2. A minimum of 40°C temperature rise is achieved at 12.6 litres/min flow rate and assume that recommended pressures and adequate
flow are available at the appliance. The actual flow rate from the appliance is automatically regulated to a maximum of 15 litres/min.
3. The domestic hot water temperature is not user adjustable.
All measurements shown are in millimetres.
BoilerMate OV PP
BoilerMate SP PP
BoilerMate SP
Summary of Contents for BOILERMATE OV PP