Page 7
Technical Specification BoilerMate OV Pre-Plumbed
Product Stock Code
BMSTOV150PP
BMSTOV180PP
BMSTOV210PP
Energy efficiency class
C
C
C
Heat loss
watts
47
55
62
kWh/24hr
1.48
1.78
2.08
Height
mm
1118
1306
1494
Diameter
mm
550
550
550
Min cupboard height
1
mm
1668
1856
2044
Min cupboard width
mm
670
670
670
Min cupboard depth
mm
670
670
670
Weight (empty)
kg
38
42
50
Weight (full)
kg
189
222
261
Thermal store volume
litres
151
181
211
DHW dedicated volume
litres
64
77
90
DHW space heating volume
litres
85
103
120
Average reheat power
2
kW
24
26
26
Average reheat time
3
mins
16
19
20
Maximum DHW pressure
bar
5
5
5
DHW performance (No space heating)
Test flow rate
litres/min
12.6
12.6
12.6
Test volume above 40°C
litres
138
154
196
Average DHW temperature
°C
54
53
52
Average temperature rise
°C
44
42
44
Thermal store test temperature
°C
75
75
75
DHW performance (Space heating)
Test flow rate
litres/min
12.6
12.6
12.6
Test volume above 40°C
litres
78
103
137
Average DHW temperature
°C
50
49
51
Average temperature rise
°C
40
37
42
Thermal store test temperature
°C
61
63
63
Notes:-
1. The height stated is to the top of the unit plus 550mm, which should allow for a 25mm thick shelf/board and room for servicing. This
will need to be increased by 125mm if the automatic fill method is chosen.
2. OV model heated by a 30kW boiler at 15 l/m.
3. Full thermal store volume reheated from 35°C to 75°C.
4. Please refer to page 5 for the minimum cupbard space requirement. This can be reduced by approximately 35mm if the insulation
is removed from the plate heat exchanger.